2011
DOI: 10.1007/s13361-010-0065-9
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Combined Standard Additions/Internal Standards Method to Quantify Residual PEG in Ethoxylated Surfactants by MALDI TOFMS

Abstract: Measuring the residual polyethylene glycol (PEG) in polyethylene oxide (PEO)-based surfactants is important to fully understanding the performance of these materials. Traditional methods of quantitating PEG in PEO-based surfactants can be time-consuming and struggle with low amounts or overlapping molecular mass distributions. This paper describes a matrixassisted laser desorption/ionization (MALDI) mass spectrometry method developed to quantitate residual PEG in a series of ethoxylated surfactants. The techni… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(21 citation statements)
references
References 29 publications
0
21
0
Order By: Relevance
“…Trimpin and coworkers [22] have shown that the latter limitation can be overcome by the use of a solvent-free sample preparation method, which has already been proven valuable in several applications [14,[16][17][18][19][20][21][22]. In addition, a few experiments were made concerning the possibility to quantify certain synthetic polymers [14,[23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%
“…Trimpin and coworkers [22] have shown that the latter limitation can be overcome by the use of a solvent-free sample preparation method, which has already been proven valuable in several applications [14,[16][17][18][19][20][21][22]. In addition, a few experiments were made concerning the possibility to quantify certain synthetic polymers [14,[23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, several parameters have been used to quantify mass spectrometry responses, including the sum of peak area, ΣI iarea [17]; the sum of peak intensity multiplying the number of repeating units in each oligomer, Σn i I i [16]; and the sum of peak intensity multiplying mass of each oligomer Σm i I i, [18,68]. Linear response has been observed using all three parameters within a narrow sample/internal standard gravimetric ratio range [16][17][18]68].…”
Section: Quantitative Analysis Of Peg1000mentioning
confidence: 99%
“…Thus, the measured mass distribution by MALDI does not necessarily reflect the true gravimetric (mass) concentration of each oligomer [12,13], which is particularly problematic for broad molecular mass distribution (MMD) polymers [14]. Nonetheless, a few studies have examined narrow MMD polymer MALDI quantitation with a closely related polymer as an internal standard [15][16][17][18]. Among these works [15][16][17][18], within a narrow analyte/internal standard gravimetric concentration ratio (~0.5-2), a linear relationship between MS signal and gravimetric concentration is reported.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations