2023
DOI: 10.1039/d2re00476c
|View full text |Cite
|
Sign up to set email alerts
|

Development of a continuous synthesis process for carbamazepine using validated in-line Raman spectroscopy and kinetic modelling for disturbance simulation

Abstract: Mitigation of failure modes in continuous synthesis (CS) of drug substance (DS) has the potential to widen the adoption of continuous manufacturing (CM) technologies by the pharmaceutical industry. This work...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(20 citation statements)
references
References 33 publications
0
20
0
Order By: Relevance
“…A BlazeMetrics (Quil Ceda Village, WA) 900 microscopy probe (Model B532) was applied to monitor batch and continuous crystallization. The development and validation of the Raman method for the quantitative measurement of CBZ and ISB is reported by Glace et al 22 2.2.3. X-ray Diffraction (XRD).…”
Section: Characterization Methods 221 High Pressure Liquid Chromatogr...mentioning
confidence: 99%
See 2 more Smart Citations
“…A BlazeMetrics (Quil Ceda Village, WA) 900 microscopy probe (Model B532) was applied to monitor batch and continuous crystallization. The development and validation of the Raman method for the quantitative measurement of CBZ and ISB is reported by Glace et al 22 2.2.3. X-ray Diffraction (XRD).…”
Section: Characterization Methods 221 High Pressure Liquid Chromatogr...mentioning
confidence: 99%
“…4−6,23−26 Continuous synthesis methods for CBZ from ISB have also been investigated but focused less to address workup or crystallization. 21,22 The available batch and continuous crystallization studies have relied upon purified commercial CBZ. 20,27−30 For the development of an advanced CM process for CBZ, it is necessary to understand the fate and removal of reaction impurities during the crystallization stages.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…PAT models are typically developed prior to CM implementation to ensure process streams are within CQA specifications. [168] In order to build an appropriate control architecture, a PAT tool is first analyzed under mock processing conditions in which a CPP is purposefully driven away from acceptable limits. The PAT tool is then assessed to determine if the technology has enough resolution to detect these variations.…”
Section: Process Analytical Technologiesmentioning
confidence: 99%
“…We were also interested in the predictive capability of our model for when the system experienced disturbances. 28,29 Thus, we simulated the influence of switching off the acrylonitrile pump at set intervals, which decreased the consumption of starting material (1). The simulated results for 1,2,4-triazole (1) are compared to the experimentallymeasured values in Fig.…”
Section: Disturbance Simulationmentioning