2015
DOI: 10.5935/0103-5053.20150192
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Multiresidue Method for Pesticide Analysis in Drinking Water by Solid Phase Extraction and Determination by Gas and Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
11
0
8

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(21 citation statements)
references
References 0 publications
2
11
0
8
Order By: Relevance
“…Out of all the CSRs tested, PDMS/PVP-DVB had the best sorption properties for 16 pesticides, with a mean increase in R of 43% compared with PDMS (PDMS/PGC (24%) and PDMS/ABN (26%)). This result is consistent with better sorption properties of Oasis R HLB sorbent for neutral compounds such as pesticides than the other SPE sorbents tested [23,24]. However, the amount of PVP-DVB incorporated in the CSR was lower for PDMS/PVP-DVB than for PDMS/PGC and PDMS/ABN (9 vs. 15%).…”
Section: Comparison Of Sorption Properties Of Composite Silicone Rubberssupporting
confidence: 83%
“…Out of all the CSRs tested, PDMS/PVP-DVB had the best sorption properties for 16 pesticides, with a mean increase in R of 43% compared with PDMS (PDMS/PGC (24%) and PDMS/ABN (26%)). This result is consistent with better sorption properties of Oasis R HLB sorbent for neutral compounds such as pesticides than the other SPE sorbents tested [23,24]. However, the amount of PVP-DVB incorporated in the CSR was lower for PDMS/PVP-DVB than for PDMS/PGC and PDMS/ABN (9 vs. 15%).…”
Section: Comparison Of Sorption Properties Of Composite Silicone Rubberssupporting
confidence: 83%
“…For carbamates, better recoveries were observed with Oasis HLB when acetonitrile rather than methanol or ethanol was used as the elution solvent (the lowest recovery observed for methomyl with all solvents) [61]. Oasis HLB, Strata-X, and Strata-C18 were also shown to provide recoveries between 70 and 120% for more pesticides when water samples were acidified to pH 2.5 for both GC-and LC-amenable pesticide classes [53]. Under the optimized method, more pesticides had acceptable recoveries with Oasis HLB as expected from this mixed-mode sorbent [53]; however, recoveries for OCs and OPs varied ( Table 2), so care should be taken if more nonpolar pesticides are of greatest interest.…”
Section: Ideas and Applications Toward Sample Preparation For Food Anmentioning
confidence: 95%
“…Oasis HLB, Strata-X, and Strata-C18 were also shown to provide recoveries between 70 and 120% for more pesticides when water samples were acidified to pH 2.5 for both GC-and LC-amenable pesticide classes [53]. Under the optimized method, more pesticides had acceptable recoveries with Oasis HLB as expected from this mixed-mode sorbent [53]; however, recoveries for OCs and OPs varied ( Table 2), so care should be taken if more nonpolar pesticides are of greatest interest. Under neutral pH conditions, recoveries for OCs and pyrethroids were also more variable when Oasis HLB was used [76].…”
Section: Ideas and Applications Toward Sample Preparation For Food Anmentioning
confidence: 99%
“…No laboratório, foi realizada a extração e análise das amostras, sendo investigados os pesticidas utilizados com frequência nas principais culturas do Rio Grande do Sul, tais como: herbicidas, inseticidas, fungicidas, nematicidas e acaricidas (Plimmer, 2001). A determinação dos agrotóxicos foi efetuada por extração em fase sólida e determinação por cromatografia gasosa e líquida de ultra-alta eficiência acoplada à espectrometria de massas em série (UHPLCMS/ MS), segundo os métodos descritos por Research, Society and Development, v. 9, n. 9, e242997128, 2020 (CC BY 4.0) | ISSN 2525-3409 | DOI: http://dx.doi.org/10.33448/rsd-v9i9.7128 Donato et al (2015) e Martins et al (2014), para amostras de água, sendo investigados 74 princípios ativos.…”
Section: Metodologiaunclassified