2009
DOI: 10.1016/j.talanta.2009.02.018
|View full text |Cite
|
Sign up to set email alerts
|

Development of a sensitive surface plasmon resonance immunosensor for detection of 2,4-dinitrotoluene with a novel oligo (ethylene glycol)-based sensor surface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
36
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 46 publications
(36 citation statements)
references
References 37 publications
0
36
0
Order By: Relevance
“…DSU has a long straight alkyl chain and a succinimidyl group in the head group; it forms a highly oriented and concentrated monolayer on Au surfaces [27]. CEG 6 is widely used as a biochemical linker because of its ability to prevent nonspecific adsorption [28][29][30][31]. C 2 -NTA is of interest to researchers because of its well-defined molecular structure and interesting properties, such as low intrinsic viscosity and solubility higher than analogues linear molecules [32].…”
Section: Introductionmentioning
confidence: 99%
“…DSU has a long straight alkyl chain and a succinimidyl group in the head group; it forms a highly oriented and concentrated monolayer on Au surfaces [27]. CEG 6 is widely used as a biochemical linker because of its ability to prevent nonspecific adsorption [28][29][30][31]. C 2 -NTA is of interest to researchers because of its well-defined molecular structure and interesting properties, such as low intrinsic viscosity and solubility higher than analogues linear molecules [32].…”
Section: Introductionmentioning
confidence: 99%
“…However, the development process is challenging owing to the lack of an explosivesensing material compatible with field application. (2) Much effort has been made to develop reliable direct explosive detection methods, such as bioreceptor-based sensing, (3,4) synthetic-material-based sensing, (5)(6)(7)(8) and Meisenheimer-complex-based sensing. (9) However, the bioreceptor and the Meisenheimer complex approaches have a sensitivity issue under a dry condition.…”
Section: Introductionmentioning
confidence: 99%
“…(2,3) In addition, we developed three kinds of sensor surfaces that are highly sensitive for the detection of nitroaromatic compounds. (4)(5)(6) However, the detection time was over 15 min in those studies, because we chose an indirect competitive assay format for highly sensitive detection of explosives. In the assay format, the antibody and antigen solutions are premixed and incubated for about 15 min before measurement.…”
Section: Introductionmentioning
confidence: 99%