2023
DOI: 10.1101/2023.03.08.531737
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Development of a Synthetic Biosensor for Chemical Exchange MRI UtilizingIn SilicoOptimized Peptides

Abstract: Chemical Exchange Saturation Transfer (CEST) magnetic resonance imaging (MRI) has been identified as a novel alternative to classical diagnostic imaging. Over the last several decades, many studies have been conducted to determine possible CEST agents, such as endogenously expressed compounds or proteins, that can be utilized to produce contrast with minimally invasive procedures and reduced or non-existent levels of toxicity. In recent years there has been an increased interest in the generation of geneticall… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…In the present study, we have focused on developing versatile pulse shapes for CEST MRI using an applied a gradient ascent algorithm to optimize the shapes for a range of Δω and k ca that are observed in the agents employed in our center including the ones evaluated but also glucose 9 , superCESTide 37, 38 , creatine 39 and others. We focused on optimizing for a 100 msec saturation pulse to be inserted into a pulse train for producing CEST MRI contrast, so these pulses are not explicitly optimized for the steady-state CEST sequences with low flip angle pulse and buildup of saturation which are also widely used on clinical scanners.…”
Section: Discussionmentioning
confidence: 99%
“…In the present study, we have focused on developing versatile pulse shapes for CEST MRI using an applied a gradient ascent algorithm to optimize the shapes for a range of Δω and k ca that are observed in the agents employed in our center including the ones evaluated but also glucose 9 , superCESTide 37, 38 , creatine 39 and others. We focused on optimizing for a 100 msec saturation pulse to be inserted into a pulse train for producing CEST MRI contrast, so these pulses are not explicitly optimized for the steady-state CEST sequences with low flip angle pulse and buildup of saturation which are also widely used on clinical scanners.…”
Section: Discussionmentioning
confidence: 99%
“…In the future, by combining peptides obtained through the evolutionary algorithm with proteins, it may be possible to achieve a stable structure without compromising the potential for enhanced detection through CEST contrast. A similar approach has been successfully employed in the generation of de novo biosensors for CEST MRI by coupling proteins with peptides exhibiting high CEST potential [28].…”
Section: Discussionmentioning
confidence: 99%
“…, LLK (28) or LKLL (17). However, there are also motifs that incorporate other AA, such as LQS (10) or SLK (16).…”
Section: Peptide Predictionsmentioning
confidence: 99%
See 2 more Smart Citations