Development of Amperometric Laccase Biosensor through Immobilizing Enzyme in Magnesium‐Containing Mesoporous Silica Sieve (Mg‐MCM‐41)/Polyvinyl Alcohol Matrix

Abstract: Magnesium-containing mesoporous silica sieve (Mg-MCM-41) provided a suitable immobilization of biomolecule matrix due to its uniform pore structure, high surface areas, fast electron-transfer rate, and good biocompatibility. Based on this, an amperometric biosensor was developed by entrapping laccase into the Mg-MCM-41/PVA composite matrix. Laccase from Trametes versicolor was assembled on a composite film of Mg-MCM-41/PVA modified Au electrode and the electrode was investigated by cyclic voltammetry, impedanc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 25 publications
1
3
0
Order By: Relevance
“…Finally, the biosensor response still retained 51.1% of the initial response after 90 days. Stability results for this biosensor were comparable with others laccase based biosensors [ 20 , 21 ]. The results reflected good reproducibility and stability of microspheres-laccase/AuNPs/SPE modified electrode suggesting acceptable storage stability.…”
Section: Resultssupporting
confidence: 83%
See 1 more Smart Citation
“…Finally, the biosensor response still retained 51.1% of the initial response after 90 days. Stability results for this biosensor were comparable with others laccase based biosensors [ 20 , 21 ]. The results reflected good reproducibility and stability of microspheres-laccase/AuNPs/SPE modified electrode suggesting acceptable storage stability.…”
Section: Resultssupporting
confidence: 83%
“…The electrode was immersed in 0.1 M PBS (pH = 5.0) when it was not in use. The electrode performance was checked daily using DPV [ 20 , 21 ].…”
Section: Methodsmentioning
confidence: 99%
“…However, PVA is susceptible to deformation at higher temperatures hence the biocatalyst can only be used for low temperature reactions [ 560 ]. To overcome that, PVA has been combined with other supports such as halloysite nanotubes [ 564 ], metal organic frameworks [ 561 ], alginate [ 377 ], xylan [ 565 ] and mesoporous silica [ 328 ].…”
Section: Supports Used For Laccase Immobilizationmentioning
confidence: 99%
“…Meso-porous silica sieve matrices possess compatibility and uniformity with respect to well-ordered pore structure, size, density, and surface characteristics. Amperometric detection of catechol has been reported where magnesium-doped mesoporous silica sieve–polyvinyl alcohol composite has been used as a matrix [ 67 ]. Li et al constructed a disposable biosensor using silica sphere on the surface of MWCNT with a screen printed electrode (SPE) for immobilizing Lac and detecting dopamine [ 68 ].…”
Section: Transduction Principle For Monitoring Phcsmentioning