2018
DOI: 10.1155/2018/2687341
|View full text |Cite
|
Sign up to set email alerts
|

Development of an Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the Se-MCM-41 Mesoporous Composite

Abstract: A new bioenzymatic glucose biosensor for selective and sensitive detection of glucose was developed by the immobilization of glucose oxidase (GOD) onto selenium nanoparticle-mesoporous silica composite (MCM-41) matrix and then prepared as a carbon paste electrode (CPE). Cyclic voltammetry was employed to probe the catalytic behavior of the biosensor. A linear calibration plot is obtained over a wide concentration range of glucose from 1 × 10−5 to 2 × 10−3 M. Under optimal conditions, the biosensor exhibits hig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(12 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…Obtained linear range is 0.5 ‐ 10 mM, LOD is 0.36 mM and LOQ is 1.21 mM. Response time for established biosensor with Cu(acac 2 pn) as mediator was 180 s. Constructed biosensor shows broader linear range compared to the values found in literature for CNT‐PDDA‐PtNPs‐GOx/CPE (1‐5 mM) and Se‐MCM‐41/GOx/CPE (0.01–2.0 mM) electrodes …”
Section: Resultsmentioning
confidence: 73%
“…Obtained linear range is 0.5 ‐ 10 mM, LOD is 0.36 mM and LOQ is 1.21 mM. Response time for established biosensor with Cu(acac 2 pn) as mediator was 180 s. Constructed biosensor shows broader linear range compared to the values found in literature for CNT‐PDDA‐PtNPs‐GOx/CPE (1‐5 mM) and Se‐MCM‐41/GOx/CPE (0.01–2.0 mM) electrodes …”
Section: Resultsmentioning
confidence: 73%
“…Numerous types of biosensors like SPR, quartz crystal microbalance (QCM), electrochemical and optical biosensors have been developed for monitoring of glucose ranges in blood by GOx [ [95] , [96] , [97] , [98] ]. In SPR optic based gluco-sensor, GO was immobilized on to the gold sensor surface and after injection of gluconic acid and hydrogen peroxide glucose detection was provided by increase the refractive index and change the plasmonic condition of SPR curves [ 99 ].…”
Section: Sensing Of Biomarkers Based On Iosmentioning
confidence: 99%
“…So the increase of loaded enzyme on the sensor surface led to improve in its sensitivity. For this purpose, with immobilizing GOx onto the selenium nanoparticle-mesoporous silica structures, an electrochemical enzymatic biosensor was developed for sensitive detection of glucose [ 95 ].…”
Section: Sensing Of Biomarkers Based On Iosmentioning
confidence: 99%
“…Looking on the bright side, researchers are aware of the potential to further develop glucose sensors until the point-of-care testing (POCT) level. [60][61][62] After that, a lot of optical sensors have been developed due to the qualitative detection-concept which is easily to observe. Unfortunately, it has poor sensitivity for quantitative measurements.…”
Section: Tio 2 /Polymer Nanohybridmentioning
confidence: 99%