2017
DOI: 10.1093/chromsci/bmx078
|View full text |Cite
|
Sign up to set email alerts
|

Development of an Analytical Method for the Determination of Amoxicillin in Commercial Drugs and Wastewater Samples, and Assessing its Stability in Simulated Gastric Digestion

Abstract: A highly sensitive analytical HPLC-UV method was developed for the determination of amoxicillin in drugs and wastewater samples at a single wavelength (230 nm). In order to substantially predict the in vivo behavior of amoxicillin, drug samples were subjected to simulated gastric conditions. The calibration plot of the method was linear from 0.050 to 500 mg L-1 with a correlation coefficient of 0.9999. The limit of detection and limit of quantitation were found to be 16 and 54 μg L-1, respectively. The percent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 38 publications
(18 citation statements)
references
References 18 publications
0
18
0
Order By: Relevance
“…Simulated gastric juice was prepared in a 50 mL volumetric flask by adding 0.10 g NaCl, 0.35 mL HCl (36–37%), and 0.16 g pepsin . Before topping up to the 50 mL mark with deionized water, the solution was spiked to a final concentration of 100 mg/L.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Simulated gastric juice was prepared in a 50 mL volumetric flask by adding 0.10 g NaCl, 0.35 mL HCl (36–37%), and 0.16 g pepsin . Before topping up to the 50 mL mark with deionized water, the solution was spiked to a final concentration of 100 mg/L.…”
Section: Methodsmentioning
confidence: 99%
“…However, HPLC takes time for stabilization and optimization of parameters such as mobile phase and flow rate. In addition to this, it requires considerable amounts of organic solvents for sample elution .…”
Section: Introductionmentioning
confidence: 99%
“…The examination was conducted in the laboratories of the Ministry of Science and Technology, Department of Environment and Water using a high-performance liquid chromate-graphy device (HPLC) model (SYKAMN) of German origin and according to the conditions mentioned in the source (P1500 pump, UV2000 detector, AS3000 automatic sampling device). (Unutkan et al, 2018) used the carrier phase consisting of (acetonitrile: methanol: phosphite bfer) according to the following ratios (10:30:60) (V/V/V), and a separation column (C18-ODS (25 CM X) was used. 4.6 mm) using an ultraviolet detector (UV -230 nm) at a flow rate (1 ml min -1 ).…”
Section: -Amoxicillinmentioning
confidence: 99%
“…A range of analytical methods has been used to detect penicillins, including mass spectrometry, chromatography, or their combination [17,18]. However, they suffer from some limitations mainly relating to sample preparation and overall complexity [19]. Hence, the need for straightforward screening measurements makes it interesting to design sensors.…”
Section: Introductionmentioning
confidence: 99%