2005
DOI: 10.1088/0957-0233/16/12/014
|View full text |Cite
|
Sign up to set email alerts
|

Development of an optical accelerometer with a DVD pick-up head

Abstract: A low-cost highly sensitive optical accelerometer is developed based on the pick-up head of a commercially available DVD. The proposed accelerometer detects the focus error signal (FES) generated by a moving object using a built-in four-quadrant photodiode. The linear range of the FES curve is employed to indicate the displacement of the seismic mass relative to the base of the accelerometer. The acceleration acting on the base is then determined on the basis of the measured displacement.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
25
0
2

Year Published

2006
2006
2021
2021

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(29 citation statements)
references
References 13 publications
0
25
0
2
Order By: Relevance
“…Este DVD lo introdujeron en una unidad de DVD extraída de un computador a la cual adjuntaron un panel. Chu & Lin (2005) desarrollaron un acelerómetro óptico que dirigía el láser de una unidad de DVD sobre la masa sísmica y utilizaba la señal de error de enfoque (FES) detectada por el fotodiodo de cuatro cuadrantes para medir el desplazamiento de la masa sísmica respecto a la base del acelerómetro. Más adelante, desarrollaron un acelerómetro óptico bi-dimensional usando este mismo concepto.…”
Section: Otras Aplicacionesunclassified
“…Este DVD lo introdujeron en una unidad de DVD extraída de un computador a la cual adjuntaron un panel. Chu & Lin (2005) desarrollaron un acelerómetro óptico que dirigía el láser de una unidad de DVD sobre la masa sísmica y utilizaba la señal de error de enfoque (FES) detectada por el fotodiodo de cuatro cuadrantes para medir el desplazamiento de la masa sísmica respecto a la base del acelerómetro. Más adelante, desarrollaron un acelerómetro óptico bi-dimensional usando este mismo concepto.…”
Section: Otras Aplicacionesunclassified
“…It is a considerable extension of an earlier paper [5] dealing with a similar device but restricted to 1D only. In the awarded paper, not only is the extension to 2D presented, but also a thorough analysis of the system's performance is given.…”
mentioning
confidence: 93%
“…Cuando se revisa el estado del arte, se encuentran aplicaciones de las unidades de CD en perfilometría [2]- [8], en microscopía de barrido [9], en microscopía de fuerza atómica [10] - [14], para desarrollar un velocímetro [15], [16], para desarrollar un interferómetro de Fizeau multifase homodino [17], para medir rectitud [18], para el desarrollo de una micro-máquina de medición por coordenadas [19] [20], para crear un pulsador electrónico [21], para desarrollar un aceleróme-tro óptico [22][23], en el desarrollo de una sonda táctil tridimensional [24], para desarrollar un biosensor óptico [25], un sistema de análisis celular [26], un sistema de micro-espectroscopia de Rhaman miniaturizado [27], para medir eventos vinculantes bio-moleculares [28], en citometría [29]- [31], para análisis de micro-estructuras [32], en la detección óptica para chips de ADN [33][34], en la detección de bio-información a partir de un bio-chip [35], para desarrollar un autocolimador [36], para detectar drogas y uniones en células biológicas [37].…”
Section: Introductionunclassified