2018
DOI: 10.1515/teme-2017-0113
|View full text |Cite
|
Sign up to set email alerts
|

Development of bioimpedance sensing device for wearable monitoring of the aortic blood pressure curve

Abstract: Wearable devices that monitor our vital signs have been gaining more importance with each year. Non-invasive, continuous, accurate and precise blood pressure assessment method integrated in a wearable is a multidisciplinary challenge. This work presents an electrical bioimpedance (EBI) unit for multi-frequency measurements on pulsating artery for central aortic pressure (CAP) estimation. The developed device provides low complexity in the electronics design with a frequency range between 1 kHz and 200 kHz. It … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…Recently, studies on wearable BIA device have been conducted, including studies on wearable BIA devices 11 , 12 , cuff-less blood pressure sensors 13 , 14 , and bioelectrical impedance spectroscopy 15 . For the wearable solutions, accurate measurement of impedance with miniature electrodes is becoming more important.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, studies on wearable BIA device have been conducted, including studies on wearable BIA devices 11 , 12 , cuff-less blood pressure sensors 13 , 14 , and bioelectrical impedance spectroscopy 15 . For the wearable solutions, accurate measurement of impedance with miniature electrodes is becoming more important.…”
Section: Introductionmentioning
confidence: 99%
“…Placement of the electrodes in relation with the wrist and radial artery is further depicted on Figure 2b. Size, distance, location and the construction of the electrodes has been experimented with and refined during longer research period and described in different papers, such as [8] and [15]. In brief summary it can be said that the optimal setup for repeatable results consists of four equally spaced electrodes of 2-4 mm diameter roughly.…”
Section: Closer Inspection Of the Measurement Situationmentioning
confidence: 99%
“…Meas. Figure 3 70.39 0.35 0.5 4.3 Reference [18] 264.57 5.6 Reference [15] 102.8 0.12 0.11 Reference [19] 0.326…”
Section: Closer Inspection Of the Measurement Situationmentioning
confidence: 99%