2019
DOI: 10.1016/j.jddst.2019.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Development of curcumin floating beads with low density materials and solubilizers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 42 publications
1
7
0
Order By: Relevance
“…As shown in Figure 10 , the SEM image of the optimized formulation of TEL-loaded oil-entrapped floating alginate beads have an almost spherical shape with rough and porous exterior surfaces, which assisted in the controlled release of the drug from the floating beads with good buoyancy. The results were in agreement with the findings obtained by Treesinchai et al in 2019 [ 54 ].…”
Section: Resultssupporting
confidence: 93%
See 2 more Smart Citations
“…As shown in Figure 10 , the SEM image of the optimized formulation of TEL-loaded oil-entrapped floating alginate beads have an almost spherical shape with rough and porous exterior surfaces, which assisted in the controlled release of the drug from the floating beads with good buoyancy. The results were in agreement with the findings obtained by Treesinchai et al in 2019 [ 54 ].…”
Section: Resultssupporting
confidence: 93%
“…The emulsification of the sesame oil in the alginate solution and the rapid gelation within the alginate gel matrices resulted in the formation of tiny oil pockets either deep within the matrices or on the surfaces of the beads. These oily pockets offered buoyancy to the beads, allowing them to float for longer periods and providing a safety margin over premature sedimentation [ 54 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The percentage swelling index of all bead formulations (F1-F9) were at first lower in SGF, in contrast with that of SIF, demonstrating a pH-sensitive swelling behaviour. This might have occurred due to shrinkage of alginate at acidic pH [46]. Therefore, higher percentage of swelling index of these beads were noticed at 30-90 min in SIF (pH 6.8).…”
Section: Bead Swelling Behaviourmentioning
confidence: 90%
“…In another effort, for treating peptic ulcer, CUR is formulated with low density material such as polypropylene foam powder, oils and various solubilizers. This biocomposite has prolonged gastro-retention time and improve insufficient CUR release [184]. This composite is a promising carrier for drug targeted at stomach using CUR formulation.…”
Section: Curcumin Based Biocomposite Formulationmentioning
confidence: 99%