2016
DOI: 10.1080/19440049.2016.1198497
|View full text |Cite
|
Sign up to set email alerts
|

Development of high-throughput multi-residue method for non-steroidal anti-inflammatory drugs monitoring in swine muscle by LC-MS/MS

Abstract: A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…The analytical merits such as correlation factor (r) ranges, accuracies, limit of detections (LOD), limit of quantifications (LOQ), precisions and recoveries were validated according to published guidelines (Castilhos et al, 2016; Gyenge‐Szabó et al, 2014).…”
Section: Methodsmentioning
confidence: 99%
“…The analytical merits such as correlation factor (r) ranges, accuracies, limit of detections (LOD), limit of quantifications (LOQ), precisions and recoveries were validated according to published guidelines (Castilhos et al, 2016; Gyenge‐Szabó et al, 2014).…”
Section: Methodsmentioning
confidence: 99%
“…Their determination as a part of rational pharmacotherapy that aims to reduce risks and achieve disease treatment goals is less common. The levels are specifically monitored either in patients with an impaired renal function when the insufficient excretion occurs or when non-compliance is suspected [ 1 , 2 ]. The pharmaceutical industry is another sector where NSAID are determined in pharmaceutical formulations to ensure safety and effectiveness of drugs [ 3 ].…”
Section: Introductionmentioning
confidence: 99%
“…The high sensitivity and selectivity achieved using GC–MS/MS and LC–MS/MS are subject to some limitations regarding multiclass analysis, especially when the method is applied to a large number of compounds (Anagnostopoulos & Miliadis, ; Castilhos, Barreto, Meneghini, & Bergold, ; Shendy, Al‐Ghobashy, Gad Alla, & Lotfy, ). In GC–MS/MS and LC–MS/MS methods, the acquisition time of each transition restricts the number of target analytes that can be scanned.…”
Section: Introductionmentioning
confidence: 99%