2022
DOI: 10.1016/j.chemosphere.2022.134427
|View full text |Cite
|
Sign up to set email alerts
|

Development of lab-on-chip biosensor for the detection of toxic heavy metals: A review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(22 citation statements)
references
References 155 publications
0
22
0
Order By: Relevance
“…This is the reason why SAM and covalently functionalized approaches have been used for achieving the redox activity of organic molecules on solid electrodes. 5,21,22 Interestingly, when the above experiment was repeated on a CB-modified GCE, i.e., GCE/CB@NQ ads , a well-defined voltammetric redox signal at an apparent standard Initially, an unstable voltammetric response of up to ten cycles was observed; after that, a stable voltammetric response was noticed. The control CV response of GCE/CB@ Cytc ads is displayed in Figure 1C, curve b, showing the absence of any specific voltammetric signal.…”
Section: Electrochemical Response Of the Nq-adsorbed Cb Modifiedmentioning
confidence: 94%
See 2 more Smart Citations
“…This is the reason why SAM and covalently functionalized approaches have been used for achieving the redox activity of organic molecules on solid electrodes. 5,21,22 Interestingly, when the above experiment was repeated on a CB-modified GCE, i.e., GCE/CB@NQ ads , a well-defined voltammetric redox signal at an apparent standard Initially, an unstable voltammetric response of up to ten cycles was observed; after that, a stable voltammetric response was noticed. The control CV response of GCE/CB@ Cytc ads is displayed in Figure 1C, curve b, showing the absence of any specific voltammetric signal.…”
Section: Electrochemical Response Of the Nq-adsorbed Cb Modifiedmentioning
confidence: 94%
“…Based on the current vs [H 2 O 2 ] plot (Figure 5B), MM kinetic parameters such as the Michaelis−Menten rate constant (K M ), the first-order catalytic rate constant for the H 2 O 2 reduction reaction (k c ), and the electron-transfer rate constant (k′ ME ) have been estimated using the following Lineweaver−Burk (LB) plot approach. 56,57 (5) wherein Γ = the surface concentration of the electroactive species (NQ) (21.3 × 10 −9 mol cm −2 ), S LB = the slope of the LB plot, and I LB = the intercept of the LB plot. Figure 5C is…”
Section: Bioelectrocatalytic Reduction Of H 2 Omentioning
confidence: 99%
See 1 more Smart Citation
“…Labs-on-a-chip (LOCs), also known as microfluidic devices, have revolutionized biomedical and chemical analysis by providing efficient, portable, and highly miniaturized solutions ( Najjar et al, 2022 ; Izadifar et al, 2023 ; Zhao et al, 2023 ). The microfluidic design of these devices enables precise control of fluid flows and processes, leading to improved accuracy and repeatability of results ( Karthik et al, 2022 ; Verma & Pandya, 2022 ). However, their high material costs and specific manufacturing processes, which need cleanroom settings, make them inaccessible to many laboratories ( Pandey et al, 2017 ; Walsh et al, 2017 ).…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, they refer to particular project concepts associated with the notion of a piezoelectric transducer-natural interface. The mechanical nature of piezoelectric detecting devices, for example, could cause issues in detecting the mechanical movement of a biosensor to test-taking care of microfluidics, and this reality can affect faulty sensor execution (Karthik et al, 2022).…”
Section: Introductionmentioning
confidence: 99%