2014
DOI: 10.1585/pfr.9.3402123
|View full text |Cite
|
Sign up to set email alerts
|

Development of Microwave Imaging Diagnostics on the HL-2A Tokamak

Abstract: Microwave imaging reflectometry (MIR) and electron cyclotron emission imaging (ECEI) systems have been developed on the HL-2A tokamak to visualize the density and temperature fluctuations. The MIR system is comprised of a quasi-optical system, a four frequency microwave source and receiver system that generate 8(poloidal) × 4(radial) × 2(toroidal) = 64 channel images of density fluctuations. The ECEI system is comprised of a quasi-optical system, a front-end 24 channel heterodyne imaging array with a tunable R… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…Three microwave interferometer systems are developed to measure the plasma line-averaged density and density fluctuations in the main plasma and divertor regions [22,23]. The multi-channel ECE and ECEI are developed to measure the electron temperature profiles and fluctuations [24][25][26][27][28][29][30]. Three frequency modulation continuous wave (FMCW) reflectometers and two amplitude modulation (AM) reflectometers are developed to measure the density profiles from low field side in the horizontal plane [31][32][33][34].…”
Section: Overview Of Microwave Diagnostics On Hl-2amentioning
confidence: 99%
See 1 more Smart Citation
“…Three microwave interferometer systems are developed to measure the plasma line-averaged density and density fluctuations in the main plasma and divertor regions [22,23]. The multi-channel ECE and ECEI are developed to measure the electron temperature profiles and fluctuations [24][25][26][27][28][29][30]. Three frequency modulation continuous wave (FMCW) reflectometers and two amplitude modulation (AM) reflectometers are developed to measure the density profiles from low field side in the horizontal plane [31][32][33][34].…”
Section: Overview Of Microwave Diagnostics On Hl-2amentioning
confidence: 99%
“…Microwave imaging diagnostic systems have made important contributions to plasma physics study and have been adopted at major fusion facilities worldwide [7,19]. The ECEI and MIR systems have been developed to visualize the two/threedimensional (2D/3D) density and temperature fluctuations on the HL-2A tokamak [12,[27][28][29][30]. The ECEI system is developed in collaboration with UC Davis [19,27,28].…”
Section: Microwave Imaging Systemsmentioning
confidence: 99%