2012
DOI: 10.1063/1.4739774
|View full text |Cite
|
Sign up to set email alerts
|

Development of multi-channel Doppler spectroscopic measurement system using 8 × 8 multianode photomultiplier tube assembly

Abstract: Using an 8 × 8 channel photomultiplier tube assembly and a single Czerny-Turner monochromator, we have developed a novel Doppler spectroscopic system which can measure the time evolutions of spectral distribution of plasma emission from eight different lines of sight simultaneously. An optical lens system is employed to couple the output of the monochromator with the detector assembly, resulting in small cross-talks less than 5% in spatial distribution together with large magnification of up to 50 in wavelengt… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…This system has eight wavelength channels in each of the spatial lines-of-sight with a time resolution of shorter than 1 ls. 18 In this experiment, we utilized the radial line-of-sight to measure the radial ion flow velocity. The plasma emission structure during magnetic reconnection shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…This system has eight wavelength channels in each of the spatial lines-of-sight with a time resolution of shorter than 1 ls. 18 In this experiment, we utilized the radial line-of-sight to measure the radial ion flow velocity. The plasma emission structure during magnetic reconnection shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Optical emission spectroscopy (OES) has been proved to be a powerful technique in plasma diagnostics [4][5][6][7]. There are mainly two kinds of OES methods, one is measurement of the spectrum of certain wavelengths by PMT and slit [2][3][4][5], the other is using two-dimensional detector arrays such as charge coupled device (CCD) or intensified charge-coupled device (iCCD) camera to provide the spatial multi-channel spectrum of a range of wavelengths [6,7]. The CCDs own various advantages including their subtle detector dimension, high sensitivity, and significant signal to noise ratio.…”
Section: Introductionmentioning
confidence: 99%
“…The Doppler spectroscopy has been applied to many plasma confinement devices [1][2][3][4]. The Doppler spectroscopy has been applied to many plasma confinement devices [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…where c is the light speed. The Doppler spectroscopy has been applied to many plasma confinement devices [1][2][3][4]. Multichannel photomultiplier tube (PMT) is often used to generate pulsed plasma, of which the discharge time is from hundreds of microseconds to tens of milliseconds.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation