2016
DOI: 10.1016/j.bdq.2016.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Development of NIST standard reference material 2373: Genomic DNA standards for HER2 measurements

Abstract: NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 25 publications
(28 citation statements)
references
References 31 publications
1
25
0
2
Order By: Relevance
“…These assays were developed for the certification of NIST cancer biomarker standards (23,24). The calculation of copy number measurements from droplet digital PCR requires an accurate measurement of the droplet size.…”
Section: Resultsmentioning
confidence: 99%
“…These assays were developed for the certification of NIST cancer biomarker standards (23,24). The calculation of copy number measurements from droplet digital PCR requires an accurate measurement of the droplet size.…”
Section: Resultsmentioning
confidence: 99%
“…Details regarding the certification of NIST SRM 2373 are available from the certificate of analysis and an article describing the development and characterization of SRM 2373. 23 The cell lines were obtained from the American Type Culture Collection (ATCC) (Manassas, VA) and grown in the NIST laboratories using the recommended culture conditions. The breast cancer cell lines have different sources, hormone sensitivity, 24 and karyotypes 25e28 ( Table 1).…”
Section: Preparation Of Cell Linesmentioning
confidence: 99%
“…The DNA samples were treated with bovine pancreatic ribonuclease A before purification to remove the enzyme. 23 All purified genomic DNA samples were prepared in buffer (10 mmol/L Tris, 0.1 mmol/L EDTA, pH 8.0) and stored at 4 C. The cell line DNA was authenticated using the AmpFLSTR Identifiler Plus PCR Amplification Kit (catalog number 4427368; Life Technologies, Carlsbad, CA) on a 3500xl Genetic Analyzer with a 36-cm capillary array and POP-4 polymer (Life Technologies). The DNA samples were analyzed both when received from the repository and when the cells were expanded to produce the genomic DNA used for the production of SRM 2373.…”
Section: Dna Extraction Identity Authentication and Reference Matermentioning
confidence: 99%
“…A call for the development of a cell line HER-2 measurement standard in 2003 19 led to a HER-2 genomic DNA standard this year (2016) 20,21 but, at least so far, no HER-2 protein standard. Other descriptions regarding the use of cell lines in IHC testing, sometimes in the context of proficiency testing, often do not characterize cell lines in terms of the number of HER-2 molecules per cell.…”
Section: Discussionmentioning