Development of Regional Pixe Facility at Panjab University Cyclotron, Chandigarh (India)

Abstract: A description of modifications in the variable energy cyclotron (VEC) Chandigarh along with the installation of Proton Induced X-ray Emission (PIXE) setup is presented. A new main magnet power supply of 400A/125V out put with ±10 ppm stability and a new stabilized solid state power supply for RF oscillator has improved the beam characteristics substantially. A new chamber has been designed to cater for Proton Induced Gamma Emission (PIGE) and Rutherford Back Scattering (RBS) along with PIXE measurements. The H… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…Identification of constituent elements of analyzed sample is done on the basis of wavelength of emitted characteristic X-rays and concentration is predicted from intensities of characteristic X-rays. These characteristic X-rays are detected by high purity germanium (HPGe) X-ray detector-GUL0035 [9].…”
Section: Pixementioning
confidence: 99%
See 1 more Smart Citation
“…Identification of constituent elements of analyzed sample is done on the basis of wavelength of emitted characteristic X-rays and concentration is predicted from intensities of characteristic X-rays. These characteristic X-rays are detected by high purity germanium (HPGe) X-ray detector-GUL0035 [9].…”
Section: Pixementioning
confidence: 99%
“…For long life time of experiment, it is necessary to do elaborate study to characterize electrode materials. In reported study, elemental analysis of glass and bakelite samples is done using PIXE facility available at Cyclotron laboratory [9], Chandigarh. Elemental analysis gives an insight in to the elemental composition of glass and bakelite electrodes; glass and bakelite electrode samples procured from local and international market are found to be having similar elemental composition.…”
Section: Introductionmentioning
confidence: 99%
“…To perform elemental analysis of 208 Pb target, Particle Induced X-ray Emission (PIXE) measurements [14] have been carried out at the Cyclotron Laboratory of Panjab University, Chandigarh. A 208 Pb target was positioned perpendicularly to the beam axis and irradiated with 2.7 MeV proton beam.…”
Section: Thickness Measurement and Characterization Of Targetsmentioning
confidence: 99%
“…Proton beam was produced from Single Dee Cyclotron situated at Panjab University, Chandigarh, India. 13 The beam size at the target position was 2 mm in diameter. The target was positioned at 90 • w.r.t.…”
Section: Pige Experimental Set-upmentioning