2018
DOI: 10.1016/j.cej.2018.01.130
|View full text |Cite
|
Sign up to set email alerts
|

Development of selective Co2+ ionic sensor based on various derivatives of benzenesulfonohydrazide (BSH) compound: An electrochemical approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 46 publications
(7 citation statements)
references
References 37 publications
2
5
0
Order By: Relevance
“…The current intensity was increased in the enhancement of the p-nitrophenol amount in the aqueous media. The identical trend is also reported for different toxin monitoring 16,5052 . In a suitable protocol, the p-nitrophenol was involved to fewer amounts of surface sites of the binary SnO 2 /CdO MCs and oxidation process of the p-nitrophenol starts gradually.…”
Section: Resultssupporting
confidence: 85%
See 1 more Smart Citation
“…The current intensity was increased in the enhancement of the p-nitrophenol amount in the aqueous media. The identical trend is also reported for different toxin monitoring 16,5052 . In a suitable protocol, the p-nitrophenol was involved to fewer amounts of surface sites of the binary SnO 2 /CdO MCs and oxidation process of the p-nitrophenol starts gradually.…”
Section: Resultssupporting
confidence: 85%
“…The resultant current value is observed maximum for p-nitrophenol compared to other compounds in identical condition by electrochemical method. This is also noted that the binary SnO 2 /CdO MCs has a quick response time with extreme sensitivity, then the present materials can exhibit extreme removal and excellent biocompatibility 22,50,52 .…”
Section: Resultsmentioning
confidence: 73%
“…b, the I‐V responses are varied with corresponding concentration of Y 3+ ion. The similar tendency of electrochemical response was reported to detect various heavy metal ions . At very early stage of detecting performance of Y 3+ ion, the smaller surface coverage on the surface of C‐PMMA/CNTs e /binder/GCE due to absorption of few molecules of Y 3+ ion and with time being, the corresponding surface coverage and reactions are increased to its steady state equilibrium saturation condition.…”
Section: Resultssupporting
confidence: 71%
“…It was notably found that the proposed sensor (GCE/CuO NPs) can be used repeatedly without significant loss of analyzing capability. 28–33 …”
Section: Resultsmentioning
confidence: 99%