2021
DOI: 10.1016/j.aca.2021.338626
|View full text |Cite
|
Sign up to set email alerts
|

Development of simple drift tube design for ion mobility spectrometry based on flexible printed circuit board material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
26
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 17 publications
(31 citation statements)
references
References 21 publications
4
26
1
Order By: Relevance
“…Tetrabutylammonium (T4) was to be used as an internal standard for quantification, and at 5 μM, it gave a single peak at 19.8 ms. This corresponds to a reduced mobility in nitrogen of 1.24 cm 2 V −1 s −1 , which is very close to the value of 1.25 cm 2 V −1 s −1 reported previously by our group for a different instrument [ 12 ] and within the range from 1.19 to 1.42 cm 2 V −1 s −1 found by Fernandez-Maestre in a literature survey [ 37 ]. As can also be seen from Fig.…”
Section: Resultssupporting
confidence: 90%
See 2 more Smart Citations
“…Tetrabutylammonium (T4) was to be used as an internal standard for quantification, and at 5 μM, it gave a single peak at 19.8 ms. This corresponds to a reduced mobility in nitrogen of 1.24 cm 2 V −1 s −1 , which is very close to the value of 1.25 cm 2 V −1 s −1 reported previously by our group for a different instrument [ 12 ] and within the range from 1.19 to 1.42 cm 2 V −1 s −1 found by Fernandez-Maestre in a literature survey [ 37 ]. As can also be seen from Fig.…”
Section: Resultssupporting
confidence: 90%
“…The instrument is based on the design reported by Reineke and Clowers and on our earlier implementation [ 2 , 12 ]. A schematic diagram of the instrument and its periphery is shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ion-mobility spectrome-try can be used in conjunction with mass spectrometry to improve the specificity of the system. [96][97][98] Consequently, the combination with nanofluidic devices will allow for further improvement in specificity. Moreover, tandem mass spectrometry is another method used to enhance specificity.…”
Section: High Level Of Specificity and Selectivitymentioning
confidence: 99%
“…In particular, target analytes are present in complex biological samples. Ion‐mobility spectrometry can be used in conjunction with mass spectrometry to improve the specificity of the system 96‐98 . Consequently, the combination with nanofluidic devices will allow for further improvement in specificity.…”
Section: Perspectivesmentioning
confidence: 99%