2019
DOI: 10.1063/1.5084621
|View full text |Cite
|
Sign up to set email alerts
|

Development of spectromicroscopes for multiscale observation of heterogeneity in materials at photon factory, IMSS, KEK

Abstract: We have developed hard X-ray spectromicroscopes at various scales using synchrotron radiation to elucidate the origin of the function of materials at Photon Factory (PF), Institute of Materials Structure Science (IMSS), High Energy Accelerator Research Organization (KEK) in Japan. One is a 2D scanning X-ray microscope with ~20-µm spatial resolution at BL-15A1 in PF; another is full-field 3D X-ray computed tomography (X-CT) with a resolution down to 30 nm at NW2A in PF-AR. In both techniques, not only morpholog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…SR-XCT measurements were performed on the NW2A beamline of the Photon Factory Advanced Ring Synchrotron facility at the Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), Japan (Niwa et al 2019). The voxel size and X-ray beam energy were maintained at 24.2 nm and 7118 eV, respectively.…”
Section: Combined Fib and X-ray Ct Analysismentioning
confidence: 99%
“…SR-XCT measurements were performed on the NW2A beamline of the Photon Factory Advanced Ring Synchrotron facility at the Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), Japan (Niwa et al 2019). The voxel size and X-ray beam energy were maintained at 24.2 nm and 7118 eV, respectively.…”
Section: Combined Fib and X-ray Ct Analysismentioning
confidence: 99%
“…We utilized the XAFS combined with computed tomography (XAFS‐CT) microscope recently installed at PF‐AR‐NW2A beamline in IMSS, KEK, Japan (Figure ). The microscope (Xradia Ultra, Carl‐Zeiss X‐ray Microscopy, Inc.) was designed to work at the photon energy range 5–11 keV.…”
Section: D Chemical‐state Mapping Of Yb In Ebcmentioning
confidence: 99%
“…We obtained the 3D distribution of chemical states of Yb in ytterbium silicates (YbÀSiÀO), a candidate for top-coat materials of next-generation EBCs. [5] We utilized the XAFS combined with computed tomography (XAFS-CT) microscope recently installed at PF-AR-NW2A beamline [19] in IMSS, KEK, Japan ( Figure 2). The microscope (Xradia Ultra, Carl-Zeiss X-ray Microscopy, Inc.) was designed to work at the photon energy range 5-11 keV.…”
Section: Introductionmentioning
confidence: 99%