Development of the system for abdominal aortic aneurysm mechanical properties research using “Bubble Inflated” method

Abstract: The main goal of this paper was to determine the biomechanical parameters of abdominal aortic aneurysm using the Bubble Inflated method. In other words, the main task of this paper was to develop a system which would be able to increase the pressure of physiological saline which affects blood vessel tissue and causes its deformation. This deformation is recorded using a camera and providing data at each moment about pressure values which affect tissue and were detected by using a pressure sen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…The sensor is supplied with a voltage 12-36 VDC, and outputs a current of 4-20 mA, which reflects the change in pressure of the physiological saline. A heater is used to heat the distilled water in order to adjust the temperature of the physiological saline to 37°C, regardless of their physical mixing, since heating the physiological saline in the heater is not allowed in order to prevent chemical reactions that could alter the composition of the physiological saline [12].…”
Section: Methodsmentioning
confidence: 99%
“…The sensor is supplied with a voltage 12-36 VDC, and outputs a current of 4-20 mA, which reflects the change in pressure of the physiological saline. A heater is used to heat the distilled water in order to adjust the temperature of the physiological saline to 37°C, regardless of their physical mixing, since heating the physiological saline in the heater is not allowed in order to prevent chemical reactions that could alter the composition of the physiological saline [12].…”
Section: Methodsmentioning
confidence: 99%
“…Additional synthetic materials were investigated using the inflation test because the materials tested were to be used under inflation in practice. Subsequent bubble inflation tests were implemented using biological tissues that included liver 32 , bovine tissue 29 , abdominal aortic aneurysm tissue 14 and thoracic aortic tissue 14,[32][33][34][35] Figure 10) 33,37 . However, simpler BIT systems have been implemented that only record peak stress and maximum deformation through optical measurements 14,29,34,35,38 .…”
Section: Pressure Through Inflationmentioning
confidence: 99%
“…Multiaxial failure properties have been studied by various groups with varying degrees of information that can be extracted from the bubble inflation test 14,[33][34][35][36][37] . Two different BIT apparatus' will be built, one that is manually pressurized with manual measurements of optical strain (Manual BIT) and the other that is automatically pressured with automated optical strain measurements (automated BIT).…”
Section: -Research Plan To Investigate Multiaxial Failure Properties mentioning
confidence: 99%
See 2 more Smart Citations