2020
DOI: 10.1016/j.measurement.2019.107103
|View full text |Cite
|
Sign up to set email alerts
|

Development of voltammetric sensor based on polyimide-MWCNT composite membrane for rapid and highly sensitive detection of paracetamol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 42 publications
(8 citation statements)
references
References 32 publications
1
7
0
Order By: Relevance
“…Therefore this supporting electrolyte (H 2 SO 4 0.25 M + KCl 0,25 M) was chosen for further analysis. Indeed, the presence of KCl salt improved the response of the sensor as indicated elsewhere [17]. The effect of pH on the diclofenac oxidation at (G-MWCNT)-CPE 3 electrode was carried out by voltammetric method in the pH range of 0.5-4.0 and for different concentrations of diclofenac (0.4, 0.7 and 1 10 À 6 mol L À 1 ) in aqueous solution, containing H 2 SO 4 0.25 M + KCl 0,25 M. Three concentrations have been used in order to compare the sensitivity of the linear variation of Ip.…”
Section: Effect Of Phsupporting
confidence: 63%
“…Therefore this supporting electrolyte (H 2 SO 4 0.25 M + KCl 0,25 M) was chosen for further analysis. Indeed, the presence of KCl salt improved the response of the sensor as indicated elsewhere [17]. The effect of pH on the diclofenac oxidation at (G-MWCNT)-CPE 3 electrode was carried out by voltammetric method in the pH range of 0.5-4.0 and for different concentrations of diclofenac (0.4, 0.7 and 1 10 À 6 mol L À 1 ) in aqueous solution, containing H 2 SO 4 0.25 M + KCl 0,25 M. Three concentrations have been used in order to compare the sensitivity of the linear variation of Ip.…”
Section: Effect Of Phsupporting
confidence: 63%
“…These polymers are known for their high temperature performance, in the 200–300 °C range, as well as chemical resistance [ 35 ]. They are employed to replace the conventional use of glass, metals, and, even, steel in a broad range of industrial applications, including membrane materials for separation [ 36 ], high temperature plastics, adhesives, dielectrics, photoresists, sensors, high temperature fuel cells, flat panel displays, aerospace applications, and chemical/petrochemical industries [ 37 ].…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the interaction between PSA and thiolated aptamer led to a noticeable rise in the amount of the Rct to 3976 Ω, indicating that the fabricated aptasensor interacted successfully with PSA ( Figure 5, curve e). PSA determination with the aptasensor Due to the higher sensitivity of the DPV technique compared to CV, determination by DPV technique is recommended; besides, DPV can lower the background current (41). The quantitative determination of PSA was achieved by DPV signals in the same solution used for CV and under the optimal experimental conditions (potential range of + 0.7 to -0.4 V interval time = 0.2 s, modulation amplitude = 0.05 V).…”
Section: Optimization Of the Analytical Parameters For Psa Determinationmentioning
confidence: 99%