2013
DOI: 10.1007/s00586-013-2993-0
|View full text |Cite
|
Sign up to set email alerts
|

Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study

Abstract: The small deviations seen are likely due to human error in the form of small variations in the surgical technique and use of software to design the prototype. This technology improves the safety profile of this fixation technique and should be further studied in clinical applications.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
32
0
4

Year Published

2016
2016
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 45 publications
(37 citation statements)
references
References 31 publications
(30 reference statements)
0
32
0
4
Order By: Relevance
“…Another solution is the use of image-based navigation templates. 3,6,7,13 One of the advantages of such templates is that the relative position between the template and the intended vertebra remains the same during the surgical procedure. However, these guides have not been used during revision surgery.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Another solution is the use of image-based navigation templates. 3,6,7,13 One of the advantages of such templates is that the relative position between the template and the intended vertebra remains the same during the surgical procedure. However, these guides have not been used during revision surgery.…”
Section: Discussionmentioning
confidence: 99%
“…3,6,7,13 However, no report has described the use of such a guide during revision surgery. The reported guides used in primary surgery have a large contact area designed by making a conventional subtraction cast model of the shape of the lamina and/or the spinous process from the initial bulk structure (Fig.…”
mentioning
confidence: 99%
“…Burtsev et al Computer 3D-modeling of patient-specific navigational template for cervical screw insertion ограничивать ее широкое распро-странение. При этом в настоящее вре-мя способ является наиболее точным для корректного введения винтов [4,6,7,10]. Немногочисленные публикации, посвященные этой проблеме, описы-вают различные варианты изготовле-ния лекал.…”
Section: рисunclassified
“…Немногочисленные публикации, посвященные этой проблеме, описы-вают различные варианты изготовле-ния лекал. Большинство этих работ посвящено навигированию в шей-ном отделе позвоночника, что сви-детельствует о наибольшей сложно-сти при введении винтов в этой обла-сти [4][5][6][7][8][9][13][14][15]. Описаны различные варианты методик от одного [4,7] до трех (для шила, сверла, винта) лекал [14,15].…”
Section: рисunclassified
See 1 more Smart Citation