Diagnostic Performance of Prostate Imaging Reporting and Data System Version 2 for Detection of Prostate Cancer: A Systematic Review and Diagnostic Meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
183
1
8

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 267 publications
(197 citation statements)
references
References 39 publications
5
183
1
8
Order By: Relevance
“…Multiparametric MRI (mpMRI) is used to guide re-biopsy in such patients and has been shown to outperform systematic TRUS biopsy for lesion detection [5]. However, studies report considerable variation in MRI performance, with sensitivity and specificity ranging from 73-100% and 8-100%, respectively [6, 7], depending on composition of the study population, radiologist experience, technical issues, and the gold standard employed. Furthermore, specificity drops from 80% to 47% when including indeterminate lesions, i.e.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Multiparametric MRI (mpMRI) is used to guide re-biopsy in such patients and has been shown to outperform systematic TRUS biopsy for lesion detection [5]. However, studies report considerable variation in MRI performance, with sensitivity and specificity ranging from 73-100% and 8-100%, respectively [6, 7], depending on composition of the study population, radiologist experience, technical issues, and the gold standard employed. Furthermore, specificity drops from 80% to 47% when including indeterminate lesions, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, specificity drops from 80% to 47% when including indeterminate lesions, i.e. Prostate Imaging-Reporting and Data System (PI-RADS) score 3 lesions in addition to score 4-5 [6, 7]. This highlights the need for improvement of existing sequences, or use of additional functional sequences, with the most recent version of the PI-RADS guidelines strongly supporting the continued development of further novel MRI sequences [8].…”
Section: Introductionmentioning
confidence: 99%
“…Woo ve ark. [9], 21 çalışmayı (3857 hasta) dahil ettikleri meta-analizin sonuçlarına göre, PIRADSv2'nin prostat kanserini tespit etmede havuzlanmış duyarlılığını %89 ve öz-güllüğünü %73 olarak bildirmektedir. Bu meta-analizde teknik yönden yapılan değerlendir-mede; endorektal koil kullanımının istatistiksel olarak anlamlı bir faktör olmadığı ve dahası 3 T'nin 1,5 T'ye klinik olarak anlamlı üstünlüğü olmadığı bildirilmektedir.…”
Section: Kaç Tesla? Hangi Koil Tercih Edilmeli?unclassified
“…Although these results seem very promising, there is significant variability in the published studies [11], depending of the number of cases and the experience of the radiologist. Lower volume centers report a negative predictive value of mpMRI as low as 63% [12] and a moderate rate of interreader agreement, even after the implementation of PI-RADS version 2 (kappa=0.478) [13].…”
Section: Introductionmentioning