2011
DOI: 10.1590/s1413-78522011000200002
|View full text |Cite
|
Sign up to set email alerts
|

Diferenças de gênero no limiar sensitivo para estimulação elétrica nervosa em adultos jovens

Abstract: Objective: To investigate gender differences in neuronal sensory threshold (NS) for transcutaneous electrical nerve stimulation (TENS) among young adults, and the probable effects of thermotherapy. Methods: 30 young healthy students (15 men and 15 women) with 22±2 years old were divided by gender. TENS was applied in both right and left knees of subjects with a frequency of 20 Hz and pulse duration of 230µs. The amplitude RI WKH HOHFWULF FXUUHQW P ZDV JUDGXDOO\ LQFUHDVHG WR UHFRUG the perception threshold (ST)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 19 publications
0
1
0
2
Order By: Relevance
“…Foram calculadas as taxas do número de atendimentos em PIC apresentados ao MS, em relação ao total de atendimentos ambulatoriais, ano a ano, e para todo o período do estudo 2009 a 2019. Para a análise do número de procedimentos das PIC por 100.000 atendimentos ambulatoriais, estimou-se modelo de regressão linear simples, definido como: Y = α + β ANO, sendo α a taxa média do números de procedimentos no período analisado e β o incremento médio no período verificado, sendo todas as afirmações e conclusões realizadas ao nível de significância de 5% (SANTOS, 2009;ROCHA, 2011;RODRIGUES, 2011). O Software utilizado neste estudo foi o Statistical Package for the Social Sciences-SPSS (versão 8.0) para análise dos dados de regressão linear simples, correlações e teste t de student não pareado.…”
Section: Métodosunclassified
“…Foram calculadas as taxas do número de atendimentos em PIC apresentados ao MS, em relação ao total de atendimentos ambulatoriais, ano a ano, e para todo o período do estudo 2009 a 2019. Para a análise do número de procedimentos das PIC por 100.000 atendimentos ambulatoriais, estimou-se modelo de regressão linear simples, definido como: Y = α + β ANO, sendo α a taxa média do números de procedimentos no período analisado e β o incremento médio no período verificado, sendo todas as afirmações e conclusões realizadas ao nível de significância de 5% (SANTOS, 2009;ROCHA, 2011;RODRIGUES, 2011). O Software utilizado neste estudo foi o Statistical Package for the Social Sciences-SPSS (versão 8.0) para análise dos dados de regressão linear simples, correlações e teste t de student não pareado.…”
Section: Métodosunclassified
“…The perception of the stimulus may also be influenced by the current somatic state of a person (health or illness), their mental state (e.g., happy, anxious, or depressed), and the physiological properties of the peripheral and central nervous system [14][15][16]. In humans, other factors that may contribute to the modification of somatosensory impressions and differences in the degree of external stimuli perception include age, sex, changing hormone levels such as during the monthly cycle in women (especially estrogen E2 and progesterone P2) [17], personality traits, and effects of endogenous opioids or medication taken, including painkillers. The perception of stimuli from the environment may also depend on genetic determinants, as well as a system of sociological and cultural beliefs in which a given person functions [18][19][20].…”
Section: Introductionmentioning
confidence: 99%
“…Um aparelho de eletroestimulação possibilita a modulação de diversos parâmetros responsáveis por determinar os diferentes tipos de estímulos e suas aplicações. Usualmente os principais parâmetros passíveis de ajustes são: a amplitude, fornecida em volts (V) para a tensão ou em ampères (A) para corrente, a largura de pulso, em milissegundos (ms), a frequência em hertz (Hz) e o intervalo entre os estímulos ou o tempo de repouso em ms (KITCHEN;BAZIN;CLAYTON, 2003;OBERT et al, 2011). Na Figura 3.7 mostra-se a influência de alguns dos parâmetros na forma de onda de eletroestimulação.…”
Section: Equipamentos De Eletroestimulação Convencionalunclassified