Abstract:The practice of lithic heat treatment creates a combination of initial dull flake scars and subsequent smooth flake scars when the implement is finished after heating. Experiments were done to test the susceptibility of dull and smooth flake scars to etching. The points were etched in 40% hydrofluoric acid for either 40 or 60 seconds. In the 40 seconds experiment, the smooth flake scars of 9 (out of 25) heated points showed less etching than the dull flake scars or no etching at all. These artefacts formed a w… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.