2024
DOI: 10.1021/jasms.3c00366
|View full text |Cite
|
Sign up to set email alerts
|

Differential Protease Specificity by Collagenase as a Novel Approach to Serum Proteomics That Includes Identification of Extracellular Matrix Proteins without Enrichment

Jade K. Macdonald,
Cassandra L. Clift,
Janet Saunders
et al.

Abstract: Circulating extracellular matrix (ECM) proteins are serological biomarkers of interest due to their association with pathologies involving disease processes such as fibrosis and cancers. In this study, we investigate the potential for serum biomarker research using differential protease specificity (DPS), leveraging alternate protease specificity as a targeting mechanism to selectively digest circulating ECM protein serum proteins. A proof-of-concept study is presented using serum from patients with cirrhotic … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 63 publications
0
2
0
Order By: Relevance
“…Increased fibrinogen levels in serum and plasma have been associated with advanced tumor stage and poor survival in hepatocellular carcinoma. ,, Through LC-MS/MS sequencing, data showed higher proportions of fibrinogen sampled from S1 compared to S3 (S1 753 spectra, 15.7%; S3 99 spectra; 2.6%) (Figures A and S ). Two fibrinogen peptides that matched the image data showed significant elevation in peak intensity in S1 tumors compared with S3 tumors.…”
Section: Resultsmentioning
confidence: 97%
See 1 more Smart Citation
“…Increased fibrinogen levels in serum and plasma have been associated with advanced tumor stage and poor survival in hepatocellular carcinoma. ,, Through LC-MS/MS sequencing, data showed higher proportions of fibrinogen sampled from S1 compared to S3 (S1 753 spectra, 15.7%; S3 99 spectra; 2.6%) (Figures A and S ). Two fibrinogen peptides that matched the image data showed significant elevation in peak intensity in S1 tumors compared with S3 tumors.…”
Section: Resultsmentioning
confidence: 97%
“…Following epitope retrieval, the tris-buffer was sequentially exchanged with HPLC-grade H 2 O by diluting three times prior to drying via a desiccator. Collagenase type III was used for localized digestion of the extracellular matrix as done previously. In addition to the manufacturer’s characterization, collagenase type III was characterized by collagen activity assays (Abcam ab196999) prior to use. The absence of tryptic activity was validated by using a colorimetric trypsin activity assay kit (Abcam ab102531).…”
Section: Experimental Proceduresmentioning
confidence: 99%