2011
DOI: 10.1016/j.atmosenv.2011.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Diffusive sampling of 25 volatile organic compounds in indoor air: Uptake rate determination and application in Flemish homes for the elderly

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(32 citation statements)
references
References 46 publications
0
32
0
Order By: Relevance
“…Diffusive sampling is an effective tool for environmental and personal exposure monitoring, as there are few limitations for deployment location. Applications have included a wide range of environmental conditions including indoor, workplace and ambient air environments, with pollutant concentrations ranging from trace to highly contaminated levels [15][16][17]. While advances of continuous analyzers have led to mobile monitoring for understanding some air quality problems, diffusive sampler surveying remains an effective approach for detailed understanding of spatial distributions with simultaneous measurements.…”
Section: Sampling Devicementioning
confidence: 99%
“…Diffusive sampling is an effective tool for environmental and personal exposure monitoring, as there are few limitations for deployment location. Applications have included a wide range of environmental conditions including indoor, workplace and ambient air environments, with pollutant concentrations ranging from trace to highly contaminated levels [15][16][17]. While advances of continuous analyzers have led to mobile monitoring for understanding some air quality problems, diffusive sampler surveying remains an effective approach for detailed understanding of spatial distributions with simultaneous measurements.…”
Section: Sampling Devicementioning
confidence: 99%
“…The retaining gaze has a pore size of 80 mesh and the wire is 0.21 mm in diameter, giving an effective area of 46% of the full area by calculation. Previous studies [15,18] assumed full cross-sectional diffusion area without considering the effective area on the retaining gauze. This assumption is questionable; however, it does not impact the determination of UR eff , since UR eff is not determined directly from the tube geometry, rather, by experiments or modelling as presented later.…”
Section: Standard Atd Tubesmentioning
confidence: 99%
“…In short-term workplace sampling, the median 8h-UR eff is 0.47 mL/min (min-max: 0.25-0.68 mL/min), corresponding to 0.23 L (0.12-0.33 L) of sampling volumes. In long-term environmental sampling, the median 7d-UR eff is 0.32 mL/min (0.13-0.43 mL/min), resulting in a median sampling volume of 3.2 L (1.3-4.3 L) at 25 • C. 6 Values in bold are measured 8-h effective uptake rates from [36]; other values are calculated using Equations (2), (4) and (5); 7 Values in bold are measured 7-day effective uptake rates from [18]; other values are calculated using Equations (2) and (11).…”
Section: Compilation Of Ideal and Effective Ursmentioning
confidence: 99%
See 2 more Smart Citations