Digital Tomosynthesis to Evaluate Fracture Healing: Prospective Comparison With Radiography and CT

Abstract: Tomosynthesis provides diagnostic information superior to that of ra diography in postoperative evaluation of wrist fractures with lower cost and radiation than CT and should be considered in fracture follow-up imaging of other bones.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
13
0
2

Year Published

2016
2016
2020
2020

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(17 citation statements)
references
References 28 publications
2
13
0
2
Order By: Relevance
“…Manufacturers, such as Hologic and GE Healthcare, offer upgrade paths for standard mammography systems to become breast tomosynthesis capable. Other than DBT, DT is also advantageous in a variety of clinical contexts, including chest, head and neck, orthopedic, and emergency imaging (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). The aims of this article are (a) to provide radiologists and radiologic technologists with knowledge about the basic facts and acquisition technique of DT, (b) to illustrate whole-body applications of DT by presenting a broad variety of clinical images, and (c) to demonstrate the clinical utilities and limitations of DT for these applications.…”
Section: Introductionmentioning
confidence: 99%
“…Manufacturers, such as Hologic and GE Healthcare, offer upgrade paths for standard mammography systems to become breast tomosynthesis capable. Other than DBT, DT is also advantageous in a variety of clinical contexts, including chest, head and neck, orthopedic, and emergency imaging (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). The aims of this article are (a) to provide radiologists and radiologic technologists with knowledge about the basic facts and acquisition technique of DT, (b) to illustrate whole-body applications of DT by presenting a broad variety of clinical images, and (c) to demonstrate the clinical utilities and limitations of DT for these applications.…”
Section: Introductionmentioning
confidence: 99%
“…In another study on 100 patients with wrist trauma [14], sensitivity of radiography for any fracture was 61-80 %, sensitivity of tomosynthesis 77-87 %, and of CT 86-95 %. It has also been used for evaluation of fracture healing [15], with similar results. In peripheral arthritis imaging, it has been shown to be better than radiography but not as good as CT [16] but almost as good as MRI in detecting erosions [17].…”
Section: Introductionmentioning
confidence: 94%
“…Dies ist ein neuartiges Verfahren bei der die Röhren-Detektor-Einheit halbkreisförmig um das Handgelenk des Patienten rotiert und aus unterschiedlichen Projektionen eine Serie von digitalen Projektionsradiogrammen erstellt [11]. In der Literatur wird die Detektionsrate von Kahnbeinfrakturen besser als die der Projektionsradiographie, jedoch schlechter als die der CT beurteilt [25,26]. Die Strahlenbelastung liegt in einer ähnlichen Größenordnung wie bei einer konventionellen Röntgendiagnostik.…”
Section: Digitale Volumentomosyntheseunclassified