“…16,18,19) In Chile, anode support system has been used in industrial electro-refining of copper scraps and blister copper granules, which claims an energy saving as high as 50%. [20][21][22][23][24] A simultaneous electroleaching-deposition process was also used to recover copper from printed circuit boards powder concentrates and achieved good experimental results. 25) However, when the Fe 2 + concentration is 1-2 g/L, 6-9 g/L and 10 g/L in the electrolyte, the current efficiency is only 94%, 79% and 71% respectively, and further the high Fe 2 + concentration increases the acid consumption obviously.…”