2023
DOI: 10.1109/tmtt.2023.3267390
|View full text |Cite
|
Sign up to set email alerts
|

Direct Permittivity Reconstruction From Power Measurements Using a Machine Learning Aided Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 34 publications
0
7
0
Order By: Relevance
“…These measurements can only be performed by using expensive vector network analyzers (VNAs) as done in the studies 15 17 , 19 , 21 , 25 28 , which are extremely expensive. To reduce the overall cost of microwave measurement setups, especially for industrial applications, equipments operating based on amplitude-only measurements such as power sensor, amplitude analyzer, or crystal diode detector could be applied as implemented in the studies 14 , 29 39 . Because the measurement setups in the studies 29 35 used reflected signals with or without transmission signals) in the analysis, directional couplers were needed to perform such measurements.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…These measurements can only be performed by using expensive vector network analyzers (VNAs) as done in the studies 15 17 , 19 , 21 , 25 28 , which are extremely expensive. To reduce the overall cost of microwave measurement setups, especially for industrial applications, equipments operating based on amplitude-only measurements such as power sensor, amplitude analyzer, or crystal diode detector could be applied as implemented in the studies 14 , 29 39 . Because the measurement setups in the studies 29 35 used reflected signals with or without transmission signals) in the analysis, directional couplers were needed to perform such measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Because the measurement setups in the studies 29 35 used reflected signals with or without transmission signals) in the analysis, directional couplers were needed to perform such measurements. On the other hand, the measurement setup used in the studies 36 39 was based on transmission-only measurements so that a simple power meter could be implemented to pick up relevant transmitted signals through the sample. Therefore, the cost of the measurement setup in the studies 14 , 36 39 is relatively lower than the cost of the measurement setups in the studies 29 35 .…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations