Abstract:Twenty-three measurements of discharge were used to determine discharge ratings for the five adjustable sluice gates, spillway, and fish ladder at McHenry Dam on the Fox River in Illinois. Discharge ratings were determined for free weir, free orifice, and submerged orifice flow regimes. Hydraulic conditions that identify flow regimes at McHenry Dam are defined by ratios between headwater depth (h 1), tailwater depth (h 3), and gate opening (h_). Flow under the sluice gates is identified as weir flow when the r… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.