2022
DOI: 10.1016/j.prosdent.2020.11.008
|View full text |Cite
|
Sign up to set email alerts
|

Displacement and performance of abutments in narrow-diameter implants with different internal connections

Abstract: Narrow-diameter implants can be used in narrow alveolar ridges, in incisor tooth sites, between convergent tooth roots, or in restricted interdental spaces. 1,2 Recent systematic reviews have reported comparable survival rates for narrow-diameter implants to those of standard diameter implants. 3,4 One common complication with single-unit implant crowns is screw loosening, which can lead to crown loosening and wear at the implant abutment connection. 5,6 When an abutment is fixed to an implant by means of a sc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 9 publications
(15 citation statements)
references
References 23 publications
0
15
0
Order By: Relevance
“…McMaster-CARR) with an elastic modulus of 1800 MPa. 18 These assemblies were then fixed to a table by using C-clamps. One PEEK Cameras were fixed on a tripod by using a custom fixation device and calibrated individually by using 1-inch glass calibration grid that had 81 dots (9 Â 9) of known spacing to establish a common world coordinate system.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…McMaster-CARR) with an elastic modulus of 1800 MPa. 18 These assemblies were then fixed to a table by using C-clamps. One PEEK Cameras were fixed on a tripod by using a custom fixation device and calibrated individually by using 1-inch glass calibration grid that had 81 dots (9 Â 9) of known spacing to establish a common world coordinate system.…”
Section: Methodsmentioning
confidence: 99%
“…Two dental implants (Zimmer TSV; Zimmer Dental), Ø4.7 × 10 mm, were inserted into prefabricated epoxy resin polymeric sleeves (G10; McMaster‐CARR) with an elastic modulus of 1800 MPa 18 . These assemblies were then fixed to a table by using C‐clamps.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A friction-style torque-controlling device (TCD) was used to tighten each crown to its respective implant. Before tightening the crowns, the reliability of the TCD was assessed by using a digital The crown-implant pairs were then mounted on mastication (Hernandez et al, 2008;Jacobs et al, 2022;Mulla et al, 2021;Nasrin et al, 2018;Yilmaz, Çakmak, et al, 2021;Yilmaz, Gouveia, et al, 2021) simulator at a 30-degree off-axis from the loading direction (ISO 14801:2007(ISO 14801: , 2007; Figure 3).…”
Section: Materials S and Me Thodsmentioning
confidence: 99%
“…[1][2][3][4][5][6] Interim abutments for narrowdiameter implants (Ø2.9 to 3.1 mm) are typically fabricated from titanium alloy, and these implants are indicated primarily in the anterior or premolar regions where esthetics is of concern. 7 Ti has been considered as the standard abutment material, but its grayish color presents a challenge to achieving…”
mentioning
confidence: 99%