1997
DOI: 10.1002/(sici)1097-0231(19970215)11:3<307::aid-rcm850>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

Disposable Emitters for On-line Capillary Zone Electrophoresis/Nanoelectrospray Mass Spectrometry

Abstract: A new method for preparing disposable microsprayers, for on-line capillary-zone electrophoresis/electrospray mass spectrometry (CZE/ES-MS) at sub-microliter per minute flow rates, is described. Different means of coupling these microsprayers to the CZE columns are presented, and compared with the more traditional one-piece capillary arrangement used for on-line CZE/ES-MS analysis. Enhancement of separation performance was obtained using capillaries coated with [(acryloylamino) propyl]trimethylammonium chloride… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
89
2

Year Published

1997
1997
2010
2010

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 116 publications
(96 citation statements)
references
References 27 publications
5
89
2
Order By: Relevance
“…As the sprayer served as the common ground for the CE and ion source, voltages for both the separation and ESI process could be independently altered. When performing sheathless CE-ESI-MS, a significant and stable EOF is of great importance to obtain good analyte signal intensities [22,[38][39][40]. Furthermore, a typical problem in CE of proteins is that they tend to adsorb onto the fused-silica capillary wall causing band broadening and changes in EOF [41,42].…”
Section: Sheathless Ce-ms Using Hsps Capillariesmentioning
confidence: 99%
“…As the sprayer served as the common ground for the CE and ion source, voltages for both the separation and ESI process could be independently altered. When performing sheathless CE-ESI-MS, a significant and stable EOF is of great importance to obtain good analyte signal intensities [22,[38][39][40]. Furthermore, a typical problem in CE of proteins is that they tend to adsorb onto the fused-silica capillary wall causing band broadening and changes in EOF [41,42].…”
Section: Sheathless Ce-ms Using Hsps Capillariesmentioning
confidence: 99%
“…Oligosaccharides were viously [29]. Samples (approximately 0.1 mg/ml in 0.1 M HCOOH) were infused to the mass spectrometer at a flow rate prepared according to the following procedure.…”
Section: Growth Of Organism and Isolation Of Lipooligosaccharide (Losmentioning
confidence: 99%
“…It was applied for the characterization of the alpha subunit of recombinant human chorionic gonadotropin by CE-MS [125]. Neutral coatings may give rise to problems with spray stability of electrospray ionization mass spectrometry, sheathless interfacing is not feasible [182,[188][189][190].…”
Section: Resolution Optimization By Changing the Relative Eof Velocitymentioning
confidence: 99%