Distance protection blocking and re-opening scheme in multi-machine power system oscillation scenes

Abstract: In view of frequent multi-machine power system oscillations in power grid which may cause traditional oscillation blocking and re-opening schemes to be completely invalid, a distance protection oscillation blocking and re-opening scheme in multi-machine power system oscillation scenes is proposed in this paper. First, the ride-through trajectory of measured impedance in multimachine power system oscillation cases and its effect on the operation characteristic of distance protection is analyzed, and the oscilla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 18 publications
0
2
0
1
Order By: Relevance
“…Segundo Mohamad et al (2012) contribuição de corrente IC, é também chamada de corrente infeed quando está em fase com IA, e como outfeed quando sua fase é oposta à de IA. A equação 1 mostra que a impedância aparente Zapp, vista pelo relé 1, do terminal A, quando a derivação (T) estar em fase com IA, é superior a impedância factual à falta: (ZAT + ZAF) (MA et al, 2018). Sendo assim, há variação em relação ao comprimento de LT para cobertura do relé de distância em situação em que o terceiro terminal não esteja presente.…”
Section: Relé De Distância Em Linhas De Três Terminaisunclassified
“…Segundo Mohamad et al (2012) contribuição de corrente IC, é também chamada de corrente infeed quando está em fase com IA, e como outfeed quando sua fase é oposta à de IA. A equação 1 mostra que a impedância aparente Zapp, vista pelo relé 1, do terminal A, quando a derivação (T) estar em fase com IA, é superior a impedância factual à falta: (ZAT + ZAF) (MA et al, 2018). Sendo assim, há variação em relação ao comprimento de LT para cobertura do relé de distância em situação em que o terceiro terminal não esteja presente.…”
Section: Relé De Distância Em Linhas De Três Terminaisunclassified
“…The abovementioned methods in the literature [6][7][8][9][10][11][12] have the advantage of using local data. However, they could not consider all possible circumstances, because of their limited access to the power network data.…”
Section: Introductionmentioning
confidence: 99%
“…To solve the problem using local data, some algorithms are proposed in the literature based on derivatives of voltage and current, fault and circuit breaker opening traveling waves, and derivative of impedance in combination with the conventional zone‐3 scheme . In Ma et al, a blocking and re‐opening scheme is proposed for distance relays to improve their performance during power swings based on calculating dynamic phasors through least squares optimization. A zone‐3 protection scheme based on combining the steady state and transient components of the voltage signal has been discussed in Kim et al However, for implementing such a high‐frequency component‐based method, special measurement devices are required.…”
Section: Introductionmentioning
confidence: 99%