2012
DOI: 10.1007/s11999-012-2350-3
|View full text |Cite
|
Sign up to set email alerts
|

Does a Prefabricated Gentamicin-impregnated, Load-bearing Spacer Control Periprosthetic Hip Infection?

Abstract: Introduction Treating deep infection following THA has been a challenge. While the standard treatment has remained a two-stage revision, spacer designs, incorporated antibiotics, and concentrations have varied. Since control of infection may relate to choice and concentration of antibiotics, it is important to report rates of control from various spacers. Questions/purposes We therefore determined (1) the rate of infection control and (2) complications associated with a prefabricated, load-bearing, gentamicini… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 22 publications
1
18
0
Order By: Relevance
“…The overall control rate (83%) is comparable to rates reported in other studies [11,25,27,38]. An ongoing criticism of the industrially premade spacer concerns the limited selection of antibiotics offered and the use of dosages less than those recommended for treatment of infections [16,38].…”
Section: Discussionsupporting
confidence: 63%
See 1 more Smart Citation
“…The overall control rate (83%) is comparable to rates reported in other studies [11,25,27,38]. An ongoing criticism of the industrially premade spacer concerns the limited selection of antibiotics offered and the use of dosages less than those recommended for treatment of infections [16,38].…”
Section: Discussionsupporting
confidence: 63%
“…These prefabricated spacers have proven to be mechanically safe [11,25,27], with a low number of complications.…”
Section: Discussionmentioning
confidence: 99%
“…The inner part of the spacer usually contains a stainless steel rod, which is covered by antibiotic loaded cement. The cement is preloaded by the manufacturer most often with 1.9 g gentamicin sulfate [3][4][5][6][7][8][9][10][11][12]. Surgeon-made spacers are intraoperatively preformed spacers ranging from hand-made techniques using a bulb syringe to fashion a femoral head, to molded systems with or wihtout a metal endo-skeleton, while in the majority of cases, metal endoskeleton was not used.…”
Section: Discussionmentioning
confidence: 99%
“…The level of evidence (level I-IV) was noted in every study according to the criteria set forth by the Oxford 2011 guidelines for level of evidence [13]. According to these guidelines, there were 3 level II, 4 level III and 36 Level IV studies (Tables 1a and 1b) [2][3][4][5][6][7][8][9][10][11][12].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation