2019
DOI: 10.1007/s42058-019-00010-5
|View full text |Cite
|
Sign up to set email alerts
|

Does GRASP affect DCE-MRI quantitative parameters and texture analysis in patients with esophageal cancer receiving preoperative neoadjuvant chemotherapy?

Abstract: Purpose To compare pharmacokinetic parameters and texture features from two dynamic contrast-enhanced (DCE) MR images [golden-angle radial sparse parallel (GRASP) and view-sharing with golden-angle radial profile (VS-GR) reconstruction], and explore their value in assessing response to neoadjuvant chemotherapy (nCT) in esophageal cancer (EC). Methods The study prospectively enrolled 30 EC patients receiving nCT before surgery. DCE-MRI scanning was performed before nCT and within 1 week before surgery. Chemothe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…All studies were performed between September 2015 and March 2017. The inclusion criteria were following [17]: 1) Patients were confirmed with stage II-III EC by esophagoscopy pathologically [18, 19], 2) 2 cycles of nCT before surgery were performed, 3) Imaging and clinical response evaluation were performed at 2 weeks after completing all the treatment. (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…All studies were performed between September 2015 and March 2017. The inclusion criteria were following [17]: 1) Patients were confirmed with stage II-III EC by esophagoscopy pathologically [18, 19], 2) 2 cycles of nCT before surgery were performed, 3) Imaging and clinical response evaluation were performed at 2 weeks after completing all the treatment. (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Radial VIBE sequence parameters were following: TR: 3.98 ms TE: 1.91 ms, flip angle: 12°, acquisition matrix: 300 × 300, FOV: 300 mm × 300 mm × 146 mm, slice thickness: 3 mm, reconstructed image voxel size: 1.0 × 1.0 × 3.0 mm 3 , radial views: 1659, scanning time: 309 s. A total of 68 period images were collected, and each period included 72 images. 10-15 mL Gadopentetate Dimeglumine Injection (0.2 ml/kg of body weight, Omniscan, GE Healthcare) was injected at a rate of 2.5 mL/s, followed by equal volume of normal saline solution to flush the tube at 20 s after the beginning of scanning by a MR-compatible automated high-pressure injector (Spectris Solaris EP, Medrad) [17].…”
Section: Methodsmentioning
confidence: 99%