Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0
4

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(25 citation statements)
references
References 34 publications
0
21
0
4
Order By: Relevance
“…Its intrinsic spatial resolution allows small voxel sizes about 250 microns, which is twice as better than usual CT, the geometry e ciency being due to a lack of septa inside the detector [10]. The other advantages are the fast acquisition times less than 5 minutes, improved signal to noise ratio due to the exclusion of electronic noise from photon and pulse counts [10,20,21]. Low dose radiation estimates to be 30 to 60% lower compared to conventional CT [10].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Its intrinsic spatial resolution allows small voxel sizes about 250 microns, which is twice as better than usual CT, the geometry e ciency being due to a lack of septa inside the detector [10]. The other advantages are the fast acquisition times less than 5 minutes, improved signal to noise ratio due to the exclusion of electronic noise from photon and pulse counts [10,20,21]. Low dose radiation estimates to be 30 to 60% lower compared to conventional CT [10].…”
Section: Discussionmentioning
confidence: 99%
“…Photon-counting detectors compared to energy-integrating integrator (EI) detectors usually found in conventional clinical CT were demonstrated to reduce the image noise and the dose in describing the ne anatomy of cadaveric wrists [19], and for the quantitative assessment of trabecular bone microarchitecture on vertebral phantoms [20]. The direct converters are based on semi-conductors, the signal generated by a single X-ray photon is short enough to decay before the next photon arrival, then the electronic signal is proportional to the energy of the incoming X-ray and compare to a threshold voltage, each threshold determinining separated energy bins [10,21].…”
Section: Introductionmentioning
confidence: 99%
“…Weiterhin ist der Mangel an Referenzdaten und das Fehlen einer Kreuzkalibrierung der bisher verfügbaren Geräte der ersten und zweiten Generation problematisch. In diesem Zu- Daten -konventionelle Röntgenaufnahme [47], digitales Röntgen [48], VFA [49][50][51], DXA [52,53], QCT [54,55], Photon Counting CT [44]. BWS/LWS: Brust-/Lendenwirbelsäule; VFA: Vertebral Fracture Analysis; DXA: Dual X-ray Absorptiometry; QCT: Quantitative Computer Tomography; AEC: Automatic Exposure Control -Standardtechnologie zur Dosisreduktion in der CT.…”
Section: Vertebrale Frakturanalyse (Vfa)unclassified
“…69 The increased spatial resolution is particularly interesting for the assessment of bone, including subchondral bone, which is thought to play an important part in the pathophysiology of OA. [70][71][72] Peña et al 73 showed that bone mineral density and bone microstructural parameters could be measured with lower image noise and better reproducibility with photon-counting CT (PCCT) compared with energy-integrating CT (EICT). Similar performance in bone parameter measurements as EICT could further be achieved while decreasing the radiation dose by a factor of 2.3.…”
Section: Spectral and Photon-counting Ct In Oa Imagingmentioning
confidence: 99%