2013
DOI: 10.1016/j.radonc.2013.04.029
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetry auditing procedure with alanine dosimeters for light ion beam therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
21
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 21 publications
(23 citation statements)
references
References 31 publications
2
21
0
Order By: Relevance
“…For end‐to‐end test procedures, two CIRS anthropomorphic phantoms were purchased and customized: a head phantom (Proton Therapy Dosimetry head phantom model 731 HN) and a pelvis phantom (Dynamic Pelvis Phantom 008P). Both phantoms were adapted to allocate different detectors (such as radiochromic films, thimble ionization chambers and Alanine detectors) in specific holders. A CT scan of the ionization chambers placed into their customized holders was performed in order to detect air pockets between the detectors and the specific holders.…”
Section: Methodsmentioning
confidence: 99%
“…For end‐to‐end test procedures, two CIRS anthropomorphic phantoms were purchased and customized: a head phantom (Proton Therapy Dosimetry head phantom model 731 HN) and a pelvis phantom (Dynamic Pelvis Phantom 008P). Both phantoms were adapted to allocate different detectors (such as radiochromic films, thimble ionization chambers and Alanine detectors) in specific holders. A CT scan of the ionization chambers placed into their customized holders was performed in order to detect air pockets between the detectors and the specific holders.…”
Section: Methodsmentioning
confidence: 99%
“…There is also an expansion of techniques such as stereotactic radiotherapy, electronic brachytherapy and proton therapy. 78 A significant number of centres will be offering these services, and there will be a requirement to identify and support the standards that can be achieved. Future audits and clinical trials will need to address the new technologies which are on the horizon and develop suitable approaches and measurement techniques.…”
Section: Looking Aheadmentioning
confidence: 99%
“…8 Since this time the detector has been mainly used in photon dosimetry, 9 but also in charged particle beams. [10][11][12][13] Most studies on neutrons have been carried out with fast neutron energies in the MeV region and without distinction of dose components. [14][15][16] Charged and uncharged ionizing particles generate radicals in alanine.…”
Section: Proton Dose D Pmentioning
confidence: 99%