1993
DOI: 10.1378/chest.103.3.920
|View full text |Cite
|
Sign up to set email alerts
|

Dosing Efficiency and Particle-size Characteristics of Pressurized Metered-dose Inhaler Aerosols in Narrow Catheters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
1

Year Published

1995
1995
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 14 publications
0
11
1
Order By: Relevance
“…Several in vitro and in vivo studies have been conducted in order to quantify the relative lung deposition efficiencies of different nebulizers and pMDIs. In vitro studies indicated that aerosol drug delivery to the lower respiratory tract can vary from 0 to 42% with nebulizers (Fuller et al , 1992; O’Doherty et al , 1992; O’Riordan et al , 1992; Thomas et al , 1993; Ari et al , 2010a) and ranges from 0.3% to 97.5% with pMDIs (MacIntyre et al , 1985; Fuller et al , 1990; Rau et al , 1992; Taylor et al , 1993; Thomas et al , 1993; Diot et al , 1995; Fink et al , 1996, 1999; Ari et al , 2010a).…”
Section: Device‐related Factorsmentioning
confidence: 99%
“…Several in vitro and in vivo studies have been conducted in order to quantify the relative lung deposition efficiencies of different nebulizers and pMDIs. In vitro studies indicated that aerosol drug delivery to the lower respiratory tract can vary from 0 to 42% with nebulizers (Fuller et al , 1992; O’Doherty et al , 1992; O’Riordan et al , 1992; Thomas et al , 1993; Ari et al , 2010a) and ranges from 0.3% to 97.5% with pMDIs (MacIntyre et al , 1985; Fuller et al , 1990; Rau et al , 1992; Taylor et al , 1993; Thomas et al , 1993; Diot et al , 1995; Fink et al , 1996, 1999; Ari et al , 2010a).…”
Section: Device‐related Factorsmentioning
confidence: 99%
“…For patients whose tracheas are intubated, the tracheal tube itself influences drug delivery. Previous studies with different sizes of tracheal tubes have shown that the total dose of drug delivered is inversely related to the length of the tube and its internal diameter . It should be noted, however, that the total dose is not the key parameter as small tubes are used when managing small patients and the dose delivered per kg body weight becomes important.…”
Section: Impact Of Respiratory Support Equipment On Drug Deliverymentioning
confidence: 99%
“…It should be noted, however, that the total dose is not the key parameter as small tubes are used when managing small patients and the dose delivered per kg body weight becomes important. Studies attempting to bypass the tracheal tube with catheters have suggested that the impact of the tracheal tube can be reduced by this approach, although this produces its own problems .…”
Section: Impact Of Respiratory Support Equipment On Drug Deliverymentioning
confidence: 99%
“…52 In vitro bench models have demonstrated 0-42% with a nebulizer and 0.3-97.5% with an MDI. [53][54][55][56][57][58][59] It was concluded that the factors listed above contributed to the wide variability in the observed results.…”
Section: Aerosol Therapymentioning
confidence: 99%