2021
DOI: 10.1002/admi.202101461
|View full text |Cite
|
Sign up to set email alerts
|

Double‐Side‐Coated Grid‐Type Mechanical Membrane Biosensor Based on AuNPs Self‐assembly and 3D Printing

Abstract: The membrane based on receptor functionalization provides a new paradigm for the development of mechanical biosensors. However, improvement of sensitivity and test accuracy is still a challenge for mechanical biosensors in practical application. Herein, a surface stress mechanical biosensor (MBioS) based on double‐side‐gold nanoparticale (AuNP)‐coated grid‐type polydimethylsiloxane (PDMS) membrane (D‐G‐MBioS) and 3D printing for human serum albumin (HSA) detection is developed. The surface stress is amplified … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 33 publications
0
10
0
Order By: Relevance
“…Au nanoparticles(AuNPs) were electrodeposited on the MWCNTs‐COOH of the electrode by chronoamperometry (CA) technique at the constant potential of −0.8 V for 500 s. The dielectric solution included 1.0 × 10 −3 m HAuCl4, 0.5 m H 2 SO 4 and 0.1 × 10 −3 m l ‐cysteine. [ 53,60 ]…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Au nanoparticles(AuNPs) were electrodeposited on the MWCNTs‐COOH of the electrode by chronoamperometry (CA) technique at the constant potential of −0.8 V for 500 s. The dielectric solution included 1.0 × 10 −3 m HAuCl4, 0.5 m H 2 SO 4 and 0.1 × 10 −3 m l ‐cysteine. [ 53,60 ]…”
Section: Methodsmentioning
confidence: 99%
“…Au nanoparticles(AuNPs) were electrodeposited on the MWCNTs-COOH of the electrode by chronoamperometry (CA) technique at the constant potential of −0.8 V for 500 s. The dielectric solution included 1.0 × 10 −3 m HAuCl4, 0.5 m H 2 SO 4 and 0.1 × 10 −3 m l-cysteine. [53,60] To fabricate the genosensor, 8 µL of the capture probe was coated onto the modified electrode surface. The capture probe was attached to the electrode surface by the formation of AuS bond between the thiol functional group at the 5-end of the capture probe with AuNPs, through the self-assembly process at room temperature overnight.…”
Section: Fabrication Of Nano-genosensormentioning
confidence: 99%
“…The rib waveguide cantilever was connected with hidden waveguides on silicon . For human serum albumin detection, a surface stress mechanical biosensor based on a double-sided Au NP-coated grid-type polydimethylsiloxane membrane and 3D printing has been developed …”
Section: Different Types Of Biosensors For Detectionmentioning
confidence: 99%
“…The potency of human serum albumin (HSA) present in normal human urine is 20 mg/mL –1 . If the HSA in urine exceeds the upper limit of this value, the risk of kidney disease is indicated . Hence, efficient detection of urinary HSA concentration can effectively diagnose and prevent kidney disease at an early stage, and it is necessary to design a biosensor that can effectively detect the concentration of HSA.…”
Section: Introductionmentioning
confidence: 99%