2014
DOI: 10.1016/j.watres.2013.11.013
|View full text |Cite
|
Sign up to set email alerts
|

Drinking water quality and formation of biofilms in an office building during its first year of operation, a full scale study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

7
73
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 77 publications
(86 citation statements)
references
References 18 publications
7
73
0
Order By: Relevance
“…Biofilms were detached from the inner surfaces of the pipe collectors by shaking for three times 10 min with sterile 2‐mm glass beads followed by rinsing with 5 ml of sterile water (Inkinen et al . ). Water (2–4 l, depending on how much water could be filtered), resuspended biofilm samples (10 ml) and reagent blanks were filtered onto 0·2‐ μ m nylon membranes (N66, Ultipor ® ; Pall Corporation, Ann Arbor, MI), preserved with RNAlater (Qiagen, Hilden, Germany) and stored in −70°C to prevent nucleic acid degradation prior to extractions (Simister et al .…”
Section: Methodsmentioning
confidence: 97%
See 2 more Smart Citations
“…Biofilms were detached from the inner surfaces of the pipe collectors by shaking for three times 10 min with sterile 2‐mm glass beads followed by rinsing with 5 ml of sterile water (Inkinen et al . ). Water (2–4 l, depending on how much water could be filtered), resuspended biofilm samples (10 ml) and reagent blanks were filtered onto 0·2‐ μ m nylon membranes (N66, Ultipor ® ; Pall Corporation, Ann Arbor, MI), preserved with RNAlater (Qiagen, Hilden, Germany) and stored in −70°C to prevent nucleic acid degradation prior to extractions (Simister et al .…”
Section: Methodsmentioning
confidence: 97%
“…qPCR assays (gene copies per ml) reported earlier by Inkinen et al . () were available from a total of five biofilm samples that were sampled at the same time and locations, as in the present study. Furthermore, Legionell a culturing results obtained using ISO 11731 method (Inkinen et al .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…From a practical standpoint, premise plumbing is extremely complex and can differ greatly between buildings, including diverse fixture types and materials, pipe surface to volume ratios, and water temperatures (NRC, 2006). Flow conditions within pluming can also vary dramatically from one point to another depending on the building layout (Inkinen et al, 2014). All these factors result in heterogeneity within and between premise plumbing environments, making it difficult to identify common sampling plans that are representative of the actual contamination by OPPPs and risk for disease transmission.…”
Section: Introductionmentioning
confidence: 99%
“…In the decision making processes, the lack of understanding the importance of a properly working water system may lead to the lack of investments on the infrastructure (Ainsworth, 2004;OECD, 2013). Furthermore, technical properties of DWDSs such as the occurrence of dead-ends in the pipeline, piping materials, diameter of pipelines in relation to the water flow and the design of the pipelines have influence on the water quality (Inkinen et al, 2014;LeChevallier et al, 1996). Thus, the site-specific DWDS properties have to be considered when planning successful monitoring schemes.…”
Section: Introductionmentioning
confidence: 99%