2011 International Conference on Electrical and Control Engineering 2011
DOI: 10.1109/iceceng.2011.6057536
|View full text |Cite
|
Sign up to set email alerts
|

Drips detection sensor of cylindrical surface capacitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…The formula suggests that the length of the copper foil is not highly related to the detectable volume of the bubbles, but the width of the foil does affect sensitivity. Considering installation difficulties and potential errors, Capacitive sensors are already used in IV infusion to monitor fluid [23][24][25][26][27] or combined with PDMS membrane technology to monitor blood pressure, oxygen saturation, and heart rate [28][29][30][31]. Currently, such methods are used for flow rate and patient indication monitoring, while this study applies the method for bubble detection.…”
Section: Methodology Of Studiesmentioning
confidence: 99%
See 2 more Smart Citations
“…The formula suggests that the length of the copper foil is not highly related to the detectable volume of the bubbles, but the width of the foil does affect sensitivity. Considering installation difficulties and potential errors, Capacitive sensors are already used in IV infusion to monitor fluid [23][24][25][26][27] or combined with PDMS membrane technology to monitor blood pressure, oxygen saturation, and heart rate [28][29][30][31]. Currently, such methods are used for flow rate and patient indication monitoring, while this study applies the method for bubble detection.…”
Section: Methodology Of Studiesmentioning
confidence: 99%
“…Figure 2 shows a cylindrical capacitor with two different dielectrics. The capacitance at the ends of the plates follows the given formula [23].…”
Section: Proposed Use Of Capacitive Sensors In Iot Medical Devicementioning
confidence: 99%
See 1 more Smart Citation
“…To benchmark the proposed techniques, the calculated capacitances using the analytical and approximate methods are compared with the data available in the literature. In reference [14], the approximate equation used to calculate the capacitance is given by;…”
Section: Casementioning
confidence: 99%
“…It is applied to identify the phase-fractions of three-phase (gas-oil-brine) petroleum carrying pipeline with steady-state flow. This method can also be used as a drips detector sensor or to monitor the post-operative multi-phase fluid flow from human body [14].…”
Section: Introductionmentioning
confidence: 99%