2015
DOI: 10.1148/radiol.2015142631
|View full text |Cite
|
Sign up to set email alerts
|

Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

Abstract: In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values in a CT image (i.e. CT number values), depending on the materials’ mass density. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT (DECT), an additional attenuation measurement is obtained with a second x-ray spectrum (i.e. a second “energy”), allowing the differentiation of multiple materials. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
1,020
0
33

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 1,252 publications
(1,061 citation statements)
references
References 95 publications
8
1,020
0
33
Order By: Relevance
“…This effect enhances the x-ray absorption by iodine due to increased photoelectric interactions and decreased Compton scattering [20]. Then CT number pairs at low energy and high energy of different materials are mapped onto a calibration diagram [29]. The material or percentage composition of a material of interest can then be estimated depending on the position in the diagram [29].…”
Section: Limitationsmentioning
confidence: 99%
See 1 more Smart Citation
“…This effect enhances the x-ray absorption by iodine due to increased photoelectric interactions and decreased Compton scattering [20]. Then CT number pairs at low energy and high energy of different materials are mapped onto a calibration diagram [29]. The material or percentage composition of a material of interest can then be estimated depending on the position in the diagram [29].…”
Section: Limitationsmentioning
confidence: 99%
“…Then CT number pairs at low energy and high energy of different materials are mapped onto a calibration diagram [29]. The material or percentage composition of a material of interest can then be estimated depending on the position in the diagram [29]. When performing iodine quantification using single energy techniques, conversion factors between the kVp setting and CT enhancement are calculated for various iodine concentrations.…”
Section: Limitationsmentioning
confidence: 99%
“…30 Another emerging area is the application of dual-energy CT in cardiac investigations. 31 In these areas, manufacturers have again used different approaches to achieve the same aim, and different aspects of scanner technology need to be considered if the efficacy of these applications is to be compared.…”
Section: Discussion and Summarymentioning
confidence: 99%
“…Contrast-enhanced dual-energy CT, in which 2 CT data sets are acquired with different x-ray spectra allowing the differentiation of the 2 materials, showed improved specificity for characterization of small renal tumors compared with conventional CT imaging [47][48][49]. However, this technique is not widely available.…”
Section: New Techniquesmentioning
confidence: 99%