2009
DOI: 10.1016/j.bios.2009.07.023
|View full text |Cite
|
Sign up to set email alerts
|

Dual-channel differential surface plasmon ellipsometry for bio-chemical sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…Later they reported the multiplexing capability of their SPR polarimetry system and compared its performance with the commercially available Nomadics SensiQ discovery system. Here, a higher signal to noise ratio as well as lower detection limit were obtained [80].…”
Section: Polarimetrymentioning
confidence: 70%
See 1 more Smart Citation
“…Later they reported the multiplexing capability of their SPR polarimetry system and compared its performance with the commercially available Nomadics SensiQ discovery system. Here, a higher signal to noise ratio as well as lower detection limit were obtained [80].…”
Section: Polarimetrymentioning
confidence: 70%
“…This immobilization process has made label-free characterization of bio-interactions possible. In 2009, Hooper et al [80] built a highly sensitive dualchannel differential phase sensitive SPR sensor and applied it for characterization of interaction between BSA, transferrin and their specific antibodies. A self assembled monolayer was first formed by injecting 1 mM solution of 16-mercaptohexadecanoic acid across the gold coated SF2 slide.…”
Section: Monitoring and Characterization Of Interactionsmentioning
confidence: 99%
“…There have been reported two types of optical systems based on the Kretschmann configuration for multi-analyte SPR sensors. [11][12][13][14][15][16][17][18][19][20][21] The first type of SPR sensor is a so-called SPR imaging sensor, where a 2-dimension CCD sensor is used for measuring reflected light from the sensor chip, on which a multi-channel or micro array was fabricated. [11][12][13][14] For example, Piliarik et al 11 reported a high-throughput SPR imaging sensor for nucleic acids, while identifying a specific bacteria pathogenous.…”
Section: Introductionmentioning
confidence: 99%
“…The second type of SPR sensor, based on the Kretschmann configuration, is that beam splitters [15][16][17] or a cylindrical lens array 18 can be used to divide a single mono-chromatic incident light beam into multi-beams. For example, Hemmi et al 15 developed this type SPR sensor by utilizing several cubic beam splitters to generate 9 beams for 9 sensing points.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation