2014
DOI: 10.1016/j.burns.2013.05.004
|View full text |Cite
|
Sign up to set email alerts
|

Dual-imaging system for burn depth diagnosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
31
0
4

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 37 publications
(38 citation statements)
references
References 14 publications
3
31
0
4
Order By: Relevance
“…However, this success is likely due to the controlled environment that these burns were created and in which our measurements were made. In a typical clinical environment, because of the variability from patient to patient and the dynamic nature of blood flow shortly after an injury, many groups have concluded that looking at changes in blood flow alone (using LDI or LSI) is generally not sufficient (less than 80% accurate) for categorizing partial thickness burn wounds during the initial 24 hours [2,5,44,45]. The advantage of LSI is that it can quickly provide blood flow information noninvasively over a large field of view without the need to scan a laser source.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, this success is likely due to the controlled environment that these burns were created and in which our measurements were made. In a typical clinical environment, because of the variability from patient to patient and the dynamic nature of blood flow shortly after an injury, many groups have concluded that looking at changes in blood flow alone (using LDI or LSI) is generally not sufficient (less than 80% accurate) for categorizing partial thickness burn wounds during the initial 24 hours [2,5,44,45]. The advantage of LSI is that it can quickly provide blood flow information noninvasively over a large field of view without the need to scan a laser source.…”
Section: Discussionmentioning
confidence: 99%
“…SFDI is also capable of measuring physiological parameters including local tissue oxygen saturation, oxygenated hemoglobin and deoxygenated hemoglobin, but none were capable of reliably distinguishing burn categories over the four days we observed the wounds. We do expect that these parameters will have the potential for quantifying the dynamic healing response of burns typically seen about one week after the initial injury [45]. We expect that this capacity will be interesting within the context of looking at various burn wound healing interventions One challenging aspect of making measurements in a clinical environment is the intrinsic variability in skin from patient to patient.…”
Section: Discussionmentioning
confidence: 99%
“…37,62,63 Her bir teknik tek başına kullanıldığında bazı yararlı yönleri olmasıyla birlikte birtakım sınırlama-lara da sahiptir. Bu nedenle farklı iki yöntemin olumlu özelliklerini kullanarak sinerjistik etki 62 Başka bir çalışmada ise konfokal mikroskopi ile polarizasyona duyarlı OCT aynı alet içerisinde birleştirilerek, dokunun yapısal bütün-lüğü ve canlılığını saptayarak daha objektif ve noninvazif yanık derinlik değerlendirmesi yapılabilmesi için daha geniş bir parametre dizisi sağlayabileceği belirlenmiştir.…”
Section: İki̇li̇ Yöntemler (Dual Modeller)unclassified
“…37 Bununla birlikte iki yöntemin tek bir alet içerisinde birleştirilmesi dışında, iki ayrı yöntemin birlikte kullanıldığı yön-temler de çalışılmaya başlanmıştır. 63 Doku kollajen yapısını değerlendiren OCT ve doku perfüzyonunu ölçen "pulse speckle imaging (PSI)" ikili model olarak yanık derinliğinin değerlendirilmesi amacıyla kullanılmış, ilk birkaç saat içerisinde yanık derinliğini ayırt etmede başarılı olduğu bildirilmiştir. Ancak, yara takibinde bu çift-görüntüleme sisteminin uygulanabilirliğini değerlendirmek için domuz model çalışmalarının devam ettiği bildirilmiştir.…”
Section: İki̇li̇ Yöntemler (Dual Modeller)unclassified
See 1 more Smart Citation