2017
DOI: 10.1016/j.bios.2017.03.027
|View full text |Cite
|
Sign up to set email alerts
|

Dual lanthanide-doped complexes: the development of a time-resolved ratiometric fluorescent probe for anthrax biomarker and a paper-based visual sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
57
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 157 publications
(57 citation statements)
references
References 22 publications
0
57
0
Order By: Relevance
“…The major advantages of fluorescence-based POC diagnostic platforms compared with colorimetric sensing methods are simplicity, high selectivity and sensitivity, low detection limits, fast response time, and ease of handling [164]. However, fluorescence-based sensors suffer from background excitation light interference, which may mislead the accuracy of the experiments.…”
Section: Fluorescence-based Aptasensors For Abused Drugsmentioning
confidence: 99%
“…The major advantages of fluorescence-based POC diagnostic platforms compared with colorimetric sensing methods are simplicity, high selectivity and sensitivity, low detection limits, fast response time, and ease of handling [164]. However, fluorescence-based sensors suffer from background excitation light interference, which may mislead the accuracy of the experiments.…”
Section: Fluorescence-based Aptasensors For Abused Drugsmentioning
confidence: 99%
“…Ratiometric measurement is an attractive property to measure due to its inherent ability to correct for environmental factors (such as varied lighting conditions and/or optical transparency of medium; especially useful on paper-based platforms) and to self-calibrate [ 52 , 53 ]. Fluorescent dyes, although have been popularly used to demonstrate FRET-based ratiometric assays, can be easily susceptible to photobleaching [ 54 ]. More recently, the use of quantum dots [ 53 , 55 , 56 ] and gold nanoclusters [ 21 ] have been more favorable choices for FRET-based sensors due to its photostability and superior intensity from background and undesired autofluorescence [ 57 ].…”
Section: Digital Processingmentioning
confidence: 99%
“…Zhang et al designed a system for detecting an anthrax biomarker, dipicolinic acid (DPA), using lanthanide-doped silica NPs ( Figure 1 b) [ 22 ]. Some fluorescent probes have already been used to detect DPA.…”
Section: Lanthanide-doped Luminescent Nanoparticles For Diagnosticmentioning
confidence: 99%
“…HClO induces ratiometric luminescence quenching by releasing Eu ions from Eu-complex. Reprinted with permission from [ 20 , 22 , 42 ].…”
Section: Figurementioning
confidence: 99%
See 1 more Smart Citation