Endoscopic Microscopy XV 2020
DOI: 10.1117/12.2543382
|View full text |Cite
|
Sign up to set email alerts
|

Dual modality multiphoton-OCT flexible endomicroscope with an integrated electromagnetic z-actuator for optical field-of-view switching and a piezo-fiber-scanner for image acquisition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…For our endoscope, the presented collection method outperforms the DCF collection, particularly at higher imaging depths. Collection efficiency limitations at increased imaging depths with DCF collection is discussed also in 9 , where a 3.3 % simulated collection efficiency at the surface was obtained with a DCF with cladding diameter of 100 μm.…”
Section: Figure 2: Simulation Results For the Collection Arm Collecti...mentioning
confidence: 97%
See 1 more Smart Citation
“…For our endoscope, the presented collection method outperforms the DCF collection, particularly at higher imaging depths. Collection efficiency limitations at increased imaging depths with DCF collection is discussed also in 9 , where a 3.3 % simulated collection efficiency at the surface was obtained with a DCF with cladding diameter of 100 μm.…”
Section: Figure 2: Simulation Results For the Collection Arm Collecti...mentioning
confidence: 97%
“…Many applications require development of specialized imaging endoscopy systems to perform diagnosis at locations that can be hard to access. So far, several endoscope systems with 2p autofluorescence imaging capability were shown in the literature [4][5][6][7][8][9][10] . Main challenge in development of 2p autofluorescence imaging systems has been the effective collection of naturally weak autofluorescence signals.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the λ -1.2 dependence of scattering length for soft tissues [ 49 , 50 ], at the average emission wavelength of 500 nm, we used the emission scattering lengths of 15 µm and 59 µm in the simulation model. For comparison, we also simulated a hypothetical scenario where our system employed DCF fluorescence collection for the objective design finalized above in conjunction with a DCF (F-SMM900, Fibercore), used in previous studies [ 24 , 28 ].…”
Section: Probe Design and Simulationsmentioning
confidence: 99%
“…Several probe systems with 2p autofluorescence imaging capability demonstrated in the literature handle autofluorescence collection mainly in two ways [ 22 33 ]. The first way uses double clad fibers (DCFs) in a way that the fiber core is dedicated to delivery of the excitation pulses and the inner cladding is reserved for autofluorescence collection [ 22 24 , 26 28 , 31 , 33 ]. The advantage here is to have the collection element axially aligned with the focal spot.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation