2012
DOI: 10.1155/2012/402179
|View full text |Cite
|
Sign up to set email alerts
|

Dual Mode Sensing with Low-Profile Piezoelectric Thin Wafer Sensors for Steel Bridge Crack Detection and Diagnosis

Abstract: Monitoring of fatigue cracking in steel bridges is of high interest to many bridge owners and agencies. Due to the variety of deterioration sources and locations of bridge defects, there is currently no single method that can detect and address the potential sources globally. In this paper, we presented a dual mode sensing methodology integrating acoustic emission and ultrasonic wave inspection based on the use of low-profile piezoelectric wafer active sensors (PWAS). After introducing the research background … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 15 publications
0
15
0
1
Order By: Relevance
“…On the other hand, parameters of the structure's elements, both structural and non-structural, determine its safety and reliability. An important issue is therefore the structural health monitoring (SHM), which is the widely undertaken subject in the national and international literature [4][5][6][7][8][9][10][11].…”
Section: Analysis Of Local Influences Versus Structural Health Monitomentioning
confidence: 99%
“…On the other hand, parameters of the structure's elements, both structural and non-structural, determine its safety and reliability. An important issue is therefore the structural health monitoring (SHM), which is the widely undertaken subject in the national and international literature [4][5][6][7][8][9][10][11].…”
Section: Analysis Of Local Influences Versus Structural Health Monitomentioning
confidence: 99%
“…Sistem (Şekil 3), bir Kablosuz Sensör ünitesi içerir. Uygun biçimde kullanıldığında, herhangi bir statik veya dinamik yüklemeden kaynaklanan titreşimlerden ötürü meydana gelen kayma ve doğal frekanslar ile ilgili sağlanan veriler, oldukça hassas ve doğru olacaktır [22], [23] , [24] , [25] , [26] , [27].…”
Section: Ksa Prosedürüunclassified
“…Shielding with coaxial cable (suggested in [8]) is certainly an option, but additional shielding of the sensor is also suggested. Delicacy of sensor/structure interface precludes direct encapsulation of the sensor in a metallic enclosure.…”
Section: Future Developmentmentioning
confidence: 99%
“…Although such a design effectively translates out-of-plane structural vibrations, sensor thickness profile is enlarged and sensitivity to in-plane vibrations is limited. Recently, there has been interest in adapting thin piezoelectric wafer active sensors (PWAS) to monitoring acoustic emission activity [7][8][9]. Studies have demonstrated that although PWAS can be used as AE sensor, it collected smaller number of hits than a conventional AE sensor and suffered from less favorable signal to noise ratio.…”
Section: Introductionmentioning
confidence: 99%