2008
DOI: 10.1063/1.2964999
|View full text |Cite
|
Sign up to set email alerts
|

Duplex multiwire proportional x-ray detector for multichord time-resolved soft x-ray and electron temperature measurements on T-10 tokamak

Abstract: Compact 64-channel multiwire proportional chamber is successfully used on T-10 and TCV tokamaks as a continuous-current soft x-ray detectors. The duplex multiwire proportional x-ray detector is a new generation of these detectors. It has been designed for simultaneous multichord measurement of plasma soft x-ray emissivity in a two spectral ranges and determination of the electron temperature by the two-absorber method. The detector consists of two identical multiwire proportional chambers filled by 90%Kr+10%CH… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 4 publications
0
3
0
1
Order By: Relevance
“…and temperature measurements over the whole collection window as a function of the radial coordinate ρ ψ , together with the error bars and a cubic spline fit with tension. The sawtooth inversion radius estimated from soft x-ray measurements with a multiwire chamber operated in the proportional regime [58] is also indicated in the figure by a dashed line. The spatial resolution of the soft x-ray measurement is ρ ψ < 0.05 at the midplane of the vacuum chamber.…”
Section: Methodsmentioning
confidence: 99%
“…and temperature measurements over the whole collection window as a function of the radial coordinate ρ ψ , together with the error bars and a cubic spline fit with tension. The sawtooth inversion radius estimated from soft x-ray measurements with a multiwire chamber operated in the proportional regime [58] is also indicated in the figure by a dashed line. The spatial resolution of the soft x-ray measurement is ρ ψ < 0.05 at the midplane of the vacuum chamber.…”
Section: Methodsmentioning
confidence: 99%
“…Детекторы AXUV обеспечивают мониторинг излучения, возникающего во время срыва из-за радиационного рассеяния и возбуждения фоновой плазмы и примесей надтепловыми электронами [28]. Внутренняя структура МГД-возмущений определялась с помощью томографических измерений интенсивности мягкого рентгеновского излучения с помощью 2D-наборов поверхностно-барьерных кремниевых диодов [29] и газовых многопроволочных детекторов [30]. Для регистрации жёсткого рентгеновского и гамма-излучения (E  ~ 0,5-3 МэВ) использовались мониторы NaI(Tl), расположенные снаружи вакуумной камеры в различных сечениях токамака Т-10.…”
Section: экспериментальная установка и диагностические системыunclassified
“…The nonthermal bursts are analysed using CdTe detectors with toroidal and orthogonal views of the plasma column, standard x-ray tomographic systems [14], x-ray gas detectors [17], silicon absolute extreme ultraviolet (AXUV) detectors [18] and electron cyclotron emission (ECE) radiometers [19] (see figure 2). An additional NaI(Tl) monitor (placed outside the tokamak vessel) is used for measurement of the nonthermal (E γ ∼ 0.5 − 3 MeV) x-ray and neutron radiation.…”
Section: Experimental Setup and Diagnosticsmentioning
confidence: 99%